首页> 外文期刊>Applied Optics >Concave reflective SU-8 photoresist gratings for flat-field integrated spectrometers
【24h】

Concave reflective SU-8 photoresist gratings for flat-field integrated spectrometers

机译:凹面反射SU-8光刻胶光栅,用于平场集成光谱仪

获取原文
获取原文并翻译 | 示例
           

摘要

On-chip spectrometry will play a leading role in the development of micro-optofluidic systems for analytical chemistry. Integrated spectrometers fabricated using a polymer-on-silicon platform have been designed, fabricated, and characterized. Reflective grating designs have been implemented using a recursive algorithm to calculate the facet positions as described by McGreer [Appl. Opt. 35, 5904 (1996)]. It is shown that the free spectral range, the output focal plane geometry, and the linear dispersion can be selected with a high degree of control independently of the chosen grating order. The polymer-on-silicon platform facilitates integration with microfluidic circuits and cost-efficient batch fabrication.
机译:片上光谱分析将在用于分析化学的微光流体系统的开发中发挥主导作用。已经设计,制造和表征了使用硅基聚合物平台制造的集成光谱仪。如McGreer [Appl.Appl.Phys.Lett。,1993,44,3257]所述,已经使用递归算法来实现反射光栅设计以计算刻面位置。选择。 35,5904(1996)]。结果表明,自由光谱范围,输出焦平面几何形状和线性色散可以不受所选光栅阶数的高度控制地进行选择。硅上聚合物平台可促进与微流体电路的集成以及具有成本效益的批量制造。