首页> 外文期刊>Applied Mathematical Modelling >Mathematical observer for 3D radiographic scanner design
【24h】

Mathematical observer for 3D radiographic scanner design

机译:3D射线扫描仪设计的数学观察器

获取原文
获取原文并翻译 | 示例
           

摘要

In the engineering processes of medical 3D radiographic scanner, detailed design elab-orates each aspect of the device with complete descriptions, which may include operating parameters as well as the scanner specifications. For assessing the developments mathematically and objectively, task-based approaches are advocated for the optimization of image quality through the scanner design and imaging parameters. In this paper, we present a framework for assessing tomosynthesis scanner performance in lung lesion signal detectability through imaging parameters such as projection frames, lesion depths and anatomical background by using Hotelling observer (HO). Moreover, a channelized Hotelling observer (CHO) with efficient choices of non-linear iterative partial least squares (NIPALS) channels is implemented to reduce the large data dimensionality for computations. Area under the receiver operating characteristic curve (AUC) is computed as an objective figure-of-merit for the performance measurement that described the entire imaging chain. The presented framework is validated with our laboratory x-ray scanner and an anthropomorphic chest phantom. In our result, the performance is evaluated as functions of AUC to the imaging parameters. Performance map shows 5 mm lung lesion detectability is worsened with cardiac projection-overlapping. Scanner performance is highly related to anatomical structures at the image background. The developed framework has presented its value on assess tomosynthesis scanner performance through anthropomorphic phantom imaging. It can be an objective method for determining scanner detailed design and imaging parameters.
机译:在医学3D射线照相扫描仪的工程过程中,详细的设计将对设备的各个方面进行详尽的描述,其中可能包括操作参数以及扫描仪规格。为了从数学上和客观上评估进展,提倡基于任务的方法,以通过扫描仪设计和成像参数来优化图像质量。在本文中,我们提出了一个框架,用于通过使用Hotelling观察器(HO)通过成像参数(例如投影框架,病变深度和解剖背景)来评估断层合成扫描仪在肺病变信号可检测性方面的性能。而且,实现了具有非线性迭代偏最小二乘(NIPALS)通道的有效选择的通道化Hotelling观测器(CHO),以减少计算的大数据维数。计算接收器工作特性曲线(AUC)下的面积,作为描述整个成像链的性能测量的客观品质因数。所提出的框架已通过我们的实验室X射线扫描仪和拟人化的胸部模型进行了验证。在我们的结果中,将性能作为AUC对成像参数的函数进行评估。性能图显示,心脏投影重叠会降低5 mm的肺部病变的可检测性。扫描仪的性能与图像背景的解剖结构高度相关。所开发的框架已经展示了其通过拟人化体模成像评估断层合成扫描仪性能的价值。它可能是确定扫描仪详细设计和成像参数的客观方法。

著录项

  • 来源
    《Applied Mathematical Modelling》 |2018年第1期|722-730|共9页
  • 作者单位

    Division of Health Physics, Institute of Nuclear Energy Research, 1000 Wenhua Rd. Jiaan Village, Longtan District, Taoyuan City 32546,Taiwan, ROC;

    Division of Health Physics, Institute of Nuclear Energy Research, 1000 Wenhua Rd. Jiaan Village, Longtan District, Taoyuan City 32546,Taiwan, ROC;

    Division of Health Physics, Institute of Nuclear Energy Research, 1000 Wenhua Rd. Jiaan Village, Longtan District, Taoyuan City 32546,Taiwan, ROC;

    Division of Health Physics, Institute of Nuclear Energy Research, 1000 Wenhua Rd. Jiaan Village, Longtan District, Taoyuan City 32546,Taiwan, ROC;

    Division of Health Physics, Institute of Nuclear Energy Research, 1000 Wenhua Rd. Jiaan Village, Longtan District, Taoyuan City 32546,Taiwan, ROC;

    Division of Health Physics, Institute of Nuclear Energy Research, 1000 Wenhua Rd. Jiaan Village, Longtan District, Taoyuan City 32546,Taiwan, ROC;

    Division of Health Physics, Institute of Nuclear Energy Research, 1000 Wenhua Rd. Jiaan Village, Longtan District, Taoyuan City 32546,Taiwan, ROC;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Model observer; X-ray imaging; Medical device;

    机译:模型观察员;X射线成像;医疗设备;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号