Technical Note: A Simple Method to Measure the Flow Rate and Volume from Tile Drainage Pump Stations

机译:技术说明:一种简单的方法来测量瓷砖排水泵站的流量和体积

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Measurement of flow characteristics both in and out of tile drainage pump stations has always been difficult. In a typical pump station, float controls are used to turn the pump on and off. Although the flow into the sump is continuous, the pump discharge is intermittent making it difficult to accurately measure with standard flow measurement devices. Indirect measurement of flow and volume was accomplished using a current switch connected to an event datalogger. The pump-on and off periods were time stamped to the nearest half second. These data, when combined with the pump characteristic curve, the sump storage volume, and lift distance provided volume and flow rate estimates for the inflow and discharge of a field scale drainage pump station. From April to November of 2008, this method was used to estimate the inflow and discharge from a pump station that handled the outflow from a 20-ha tile drained field. The accuracy of the flow rate estimation was compared to the values obtained from the manufacturer's pump curve. The maximum difference was 3.5% between the two values
机译:一直很难测量瓷砖排水泵站内外的流量特性。在典型的泵站中,使用浮动控件来打开和关闭泵。尽管流入集液槽的流量是连续的,但泵的排放是间歇性的,因此很难使用标准流量测量设备进行精确测量。使用连接到事件数据记录器的电流开关可以间接测量流量和体积。泵的开启和关闭时间都标记为最接近的半秒。这些数据与泵的特性曲线,油底壳的存储量和升程距离结合起来,为现场规模的排水泵站的流入和排放量提供了流量和流量估算。从2008年4月至11月,使用此方法来估算处理20公顷瓷砖排水场流出水的泵站的进水和出水量。将流量估算的准确性与从制造商的泵曲线获得的值进行比较。两个值之间的最大差异为3.5%

著录项

  • 来源
    《Applied Engineering in Agriculture》 |2010年第1期|p.79-83|共5页
  • 作者

    T. F. Scherer; X. Jia;

  • 作者单位

    NDSU. The authors are Thomas F. Scherer, ASABE Member Engineer, Associate Professor, Extension Specialist, and Xinhua Jia, ASABE Member Engineer, Assistant Professor, Department of Agricultural and Biosystems Engineering, North Dakota State University, Fargo, North Dakota. Corresponding author: Thomas F. Scherer, Department of Agricultural and Biosystems Engineering, North Dakota State University, NDSU Dept. 7620, P.O. Box 6050, Fargo, ND 58108;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Tile drainage; Drainage discharge; Flow measurement; Pump station; Sump; Current sensor; Datalogger;

    机译:瓷砖排水;排水排放;流量测量;泵站;污水坑;电流传感器;数据记录仪;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号