首页> 外文期刊>Applied Energy >Outdoor overall performance of a novel air-gap-lens-walled compound parabolic concentrator (ALCPC) incorporated with photovoltaic/thermal system
【24h】

Outdoor overall performance of a novel air-gap-lens-walled compound parabolic concentrator (ALCPC) incorporated with photovoltaic/thermal system

机译:结合了光伏/热力系统的新型气隙透镜壁复合抛物线聚光器(ALCPC)的室外总体性能

获取原文
获取原文并翻译 | 示例
       

摘要

A novel air-gap-lens-walled compound parabolic concentrator incorporated with photovoltaic/thermal system (ALCPC-PV/T) was proposed. The optical, electrical and thermal performances of the ALCPC-PV/T under the outdoor condition were analyzed for building integrated concentrating photovoltaic/thermal application. The simulation and experiment were carried out to reveal the optical characteristics of ALCPC-PV/T on two typical days. The experiment results verified the optical simulation results that the ALCPC-PV/T system had a half acceptance angle of 35 and an average optical efficiency of 83.0% within the half acceptance angle for direct incidence. Furthermore, the average optical efficiencies on the two typical days were all above 60% under the actual outdoor condition considering direct and diffuse solar radiation. Details of electrical characteristics affected by the temperature of circulating cooling water were also displayed. The electrical and thermal efficiencies of the ALCPC-PV/T system during the test were 6.0% and 35.0% respectively with the final water temperature of 70 degrees C. In addition, the fitted results indicated that under the zero reduced temperature condition, the thermal efficiency of the ALCPC PV/T system was 52.0%, and the corresponding electrical efficiency was 6.6%. (C) 2015 Elsevier Ltd. All rights reserved.
机译:提出了一种结合光伏/热力系统的新型气隙透镜壁复合抛物面聚光器(ALCPC-PV / T)。分析了ALCPC-PV / T在室外条件下的光学,电学和热学性能,用于建筑集成聚光光伏/热力应用。通过仿真和实验,揭示了两天典型ALCPC-PV / T的光学特性。实验结果验证了光学仿真结果,ALCPC-PV / T系统的半入射角为35°,在半入射角内的直接入射平均光学效率为83.0%。此外,考虑到直接和漫射的太阳辐射,在实际室外条件下,两个典型天的平均光学效率均高于60%。还显示了受循环冷却水温度影响的电气特性的详细信息。在最终水温为70摄氏度的情况下,ALCPC-PV / T系统在测试过程中的电效率和热效率分别为6.0%和35.0%。此外,拟合结果表明在零降温条件下,热ALCPC PV / T系统的效率为52.0%,相应的电效率为6.6%。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Applied Energy》 |2015年第15期|214-223|共10页
  • 作者单位

    Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China|Univ Nottingham, Inst Sustainable Energy Technol, Nottingham NG7 2RD, England;

    Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China|Univ Nottingham, Inst Sustainable Energy Technol, Nottingham NG7 2RD, England;

    Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China;

    Univ Nottingham, Inst Sustainable Energy Technol, Nottingham NG7 2RD, England;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    PV/T; CPC; Air-gap; Lens-walled; Optical;

    机译:PV / T;CPC;气隙;透镜壁;光学;
  • 入库时间 2022-08-18 00:08:42

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号