首页> 外文期刊>Annals of Occupational Hygiene >Comparing the Level of Dexterity offered by Latex and Nitrile SafeSkin Gloves
【24h】

Comparing the Level of Dexterity offered by Latex and Nitrile SafeSkin Gloves

机译:比较乳胶和丁腈SafeSkin手套提供的敏捷度

获取原文
获取原文并翻译 | 示例
       

摘要

An increase in the occurrence of latex allergy has been concurrent with the increasing use of latex gloves by laboratory and healthcare workers. In recent years nitrile gloves have been used to replace latex gloves to prevent latex allergy. Nitrile gloves offer a comparable level of protection against chemical and biological agents and are more puncture resistant. However, if manual dexterity is compromised by nitrile gloves to a greater degree than latex then this may increase the risk of sharps injuries. The Purdue pegboard test, which measures both gross and fine finger dexterity, was used to test the dexterity levels of two glove types used at HPA CEPR; Kimberly-Clark SafeSkin nitrile and latex laboratory gloves. There was a statistically significant 8.6% increase in fine finger dexterity provided by latex compared with nitrile SafeSkin laboratory gloves but no difference in gross dexterity between the glove types. There was no significant relationship between glove dexterity and age or gender. The selection of glove size was influenced by the digit length of participants. Moreover, those with longer, thinner fingers appeared to have an advantage when using nitrile SafeSkin gloves. The level of dexterity provided by latex and nitrile SafeSkin gloves for tasks on a gross dexterity level are comparable and health workers will benefit from the non-allergenic properties of nitrile. For tasks requiring fine finger dexterity nitrile SafeSkin gloves may impede dexterity. Despite this, the degree of restriction appears to have a negligible impact on safety in this study when compared with the risk of latex sensitization and subsequent allergy. In addition to glove material, working practices must also take into account glove size, fit, grip and thickness, as these factors can all influence dexterity.
机译:乳胶过敏的发生率增加与实验室和医护人员对乳胶手套的使用增加有关。近年来,丁腈手套已被用来代替乳胶手套,以防止乳胶过敏。丁腈手套可提供相当水平的化学和生物制剂防护,并且更耐穿刺。但是,如果丁腈手套比乳胶对手灵巧性的危害程度更大,则可能增加锐器受伤的风险。 Purdue钉板测试可同时测量手指的手指和手指的敏捷度,用于测试HPA CEPR所使用的两种手套的敏捷度。 Kimberly-Clark SafeSkin丁腈和乳胶实验室手套。与丁腈SafeSkin实验室手套相比,乳胶提供的精细手指敏捷度在统计学上有显着提高8.6%,但两种手套之间的总敏捷度没有差异。手套的灵活性与年龄或性别之间没有显着关系。手套尺寸的选择受参与者手指长度的影响。此外,在使用丁腈SafeSkin手套时,手指较长,较细的人似乎具有优势。乳胶手套和丁腈橡胶SafeSkin手套在总体灵巧性水平上提供的灵活性水平是可比的,卫生工作者将从丁腈的非过敏性特性中受益。对于要求精细手指灵活性的任务,丁腈SafeSkin手套可能会妨碍灵活性。尽管如此,与乳胶致敏和随后的过敏风险相比,本研究中的限制程度对安全性的影响似乎可以忽略不计。除手套材料外,工作方法还必须考虑手套的尺寸,合身性,抓地力和厚度,因为这些因素都会影响灵活性。

著录项

  • 来源
    《Annals of Occupational Hygiene》 |2006年第3期|289-296|共8页
  • 作者

    JO SAWYER and ALLAN BENNETT;

  • 作者单位

    Department of Biosafety Health Protection Agency Centre for Emergency Preparedness and Response Porton Down Porton Salisbury Wiltshire SP4 0JG UK;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 01:11:31

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号