首页> 外文期刊>Annals of nuclear energy >A quantitative evaluation of reliability of passive systems within probabilistic safety assessment framework for VHTR
【24h】

A quantitative evaluation of reliability of passive systems within probabilistic safety assessment framework for VHTR

机译:在VHTR概率安全评估框架内对被动系统的可靠性进行定量评估

获取原文
获取原文并翻译 | 示例
           

摘要

This article presents a quantitative evaluation of the reliability of passive systems (RoPS) within the probabilistic safety assessment (PSA) framework for very high temperature reactors (VHTR). VHTRs have unfavorable features in regard to defining a robust failure state. From the viewpoint of PSA, the evaluation of the RoPS as a part of VHTR's PSA should carefully consider the correct status of a passive system in order to resolve these unfavorable features. This article focuses on the application of multiple states criteria to determine the status of a passive system. Two approaches, i.e., the exceedance probability (EP) model and the stress-strength interference (SSI) model were proposed for the multiple states of the system. A feasibility study has examined the basic features of the proposed approaches by using the reactor cavity cooling system (RCCS) for Korean VHTR. The primary condition for the usefulness of the proposed approaches is that sufficient information should be provided in order to determine the system strengths for the multiple states. With regard to the engineering practice, the EP approach for the multiple states can provide a practical solution concerning the evaluation of the RoPS for VHTR's PSA.
机译:本文介绍了在极高温反应堆(VHTR)的概率安全评估(PSA)框架内对被动系统(RoPS)可靠性的定量评估。 VHTR在定义可靠的故障状态方面具有不利的功能。从PSA的角度来看,作为VHTR PSA一部分的RoPS评估应仔细考虑被动系统的正确状态,以解决这些不利功能。本文着重于应用多个状态标准来确定被动系统的状态。针对系统的多个状态,提出了两种方法,即超越概率模型(EP)和应力强度干扰模型(SSI)。可行性研究已经通过使用韩国VHTR的反应堆腔冷却系统(RCCS)检验了所提出方法的基本特征。所提出方法的有用性的主要条件是,应提供足够的信息,以便确定多个状态的系统强度。关于工程实践,针对多个状态的EP方法可以为VHTR的PSA的RoPS评估提供实用的解决方案。

著录项

  • 来源
    《Annals of nuclear energy》 |2010年第3期|345-358|共14页
  • 作者

    Seok-Jung Han; Joon-Eon Yang;

  • 作者单位

    Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, P.O. Box 105, Duckjin-Dong, Yuseong-Gu, Daejon 305-600, Republic of Korea;

    Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, P.O. Box 105, Duckjin-Dong, Yuseong-Gu, Daejon 305-600, Republic of Korea;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng