首页> 外文期刊>Annals of nuclear energy >Numerical simulation of a 374 tons/h water-tube steam boiler following a feedwater line break
【24h】

Numerical simulation of a 374 tons/h water-tube steam boiler following a feedwater line break

机译:给水管线中断后374吨/小时水管式蒸汽锅炉的数值模拟

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

To ensure the operational safety of an industrial water-tube steam boiler it is very important to assess various accident scenarios in real plant working conditions. One of the most challenging scenarios is the loss of feedwater to the steam boiler. In this paper, a simulation of the behavior of an industrial water-tube radiant steam boiler during feedwater line break accident is discussed. The simulation is carried out using the RELAP5 system code. The steam boiler is installed in an Algerian natural gas liquefaction complex. The simulation shows the capabilities of RELAP5 system code in predicting the behavior of the steam boiler at both steady state and transient working conditions. From another side, the behavior of the steam boiler following the accident shows how the control system can successfully mitigate the effects and consequences of such accident and how the evaporator tubes can undergo a severe damage due to an uncontrolled increase of the wall temperature in case of failure of this system. (C) 2016 Elsevier Ltd. All rights reserved.
机译:为了确保工业水管蒸汽锅炉的运行安全,评估实际工厂工作条件下的各种事故情况非常重要。最具挑战性的情况之一是蒸汽锅炉的给水损失。本文讨论了工业水管辐射蒸汽锅炉在给水管线断裂事故中的行为模拟。使用RELAP5系统代码进行仿真。蒸汽锅炉安装在阿尔及利亚的天然气液化工厂中。仿真显示了RELAP5系统代码在预测蒸汽锅炉在稳态和瞬态工况下的行为的能力。从另一方面来看,事故发生后蒸汽锅炉的运行情况表明,控制系统如何能够成功减轻此类事故的影响和后果,以及在发生以下情况时,由于壁温不受控制的升高,蒸发器管会遭受严重损坏。该系统故障。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号