首页> 外文期刊>Annals of nuclear energy >Validation of the MCU-PTR computational model of beryllium poisoning using selected experiments at the IRT-T research reactor
【24h】

Validation of the MCU-PTR computational model of beryllium poisoning using selected experiments at the IRT-T research reactor

机译:使用IRT-T研究堆上的选定实验验证铍中毒的MCU-PTR计算模型

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents the results of the validation of the MCU-PTR code computational model of beryllium poisoning caused by He-3 and Li-6 buildup against selected experiments at the IRT-T research reactor in the National Research Tomsk Polytechnic University. Calculations including the reflector irradiation history modeling for the entire reactor lifetime were performed using the continuous energy Monte Carlo code MCU-PTR. The measured reactivity loss (similar to 3.2%Delta k/k) after the reactor shutdown period of 672 days and the reactivity increase (0.9%Delta k/k) after replacement of the part of the reflector beryllium blocks by fresh blocks were compared with the calculated results. The impact of the parameters of beryllium poisoning model on the calculated results was investigated. The calculation underestimates the reactivity loss caused by He-3 buildup during the 672-day shutdown by approximately 0.5%Delta k/k. (C) 2017 Elsevier Ltd. All rights reserved.
机译:本文介绍了针对国立托木斯克工业大学IRT-T研究反应堆的选定实验对He-3和Li-6堆积引起的铍中毒的MCU-PTR代码计算模型的验证结果。使用连续能量蒙特卡罗代码MCU-PTR进行了包括整个反应堆寿命的反射器辐照历史模型在内的计算。将反应器停机672天后测得的反应性损失(类似于3.2%Delta k / k)和将反射器铍块部分替换为新鲜块后的反应性增加(0.9%Delta k / k)与计算结果。研究了铍中毒模型参数对计算结果的影响。该计算低估了在672天停机期间由He-3堆积引起的反应性损失,大约降低了0.5%Delta k / k。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号