首页> 外文期刊>Analytical Letters >Protein-Incorporated Serum Total Antioxidant Capacity Measurement by a Modified CUPRAC (CUPRIC Reducing Antioxidant Capacity) Method
【24h】

Protein-Incorporated Serum Total Antioxidant Capacity Measurement by a Modified CUPRAC (CUPRIC Reducing Antioxidant Capacity) Method

机译:通过改良的CUPRAC(降低CUPRIC的抗氧化能力)方法测量蛋白质结合的血清总抗氧化能力

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Due to inadequacies in analytical methodology of total antioxidant capacity (TAC) measurement, proteins are initially separated from the human serum matrix by precipitation and are left unmeasured, thereby causing an important “antioxidant gap.” The aim of this work is to measure the TAC of serum with the modified CUPric Reducing Antioxidant Capacity (CUPRAC) method, and to identify the contribution of serum proteins, especially thiol-containing proteins, to TAC. CUPRAC results were statistically compared to those found by reference methods, namely ABTS (2,2′-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid), FRAP (ferric reducing antioxidant power), and Ellman thiols assay. The curves of absorbance vs thiol concentration, as well as of absorbance vs diluted serum (whole serum, trichloroacetic acid (TCA)−precipitated and redissolved serum protein solution, and TCA supernatant fractions) volume, of three distinct serum samples showed excellent linearity and low intercept values only with the modified CUPRAC method. The proposed method will help characterize the “antioxidant gap” of serum TAC originating from protein components which should not be neglected in future antioxidant measurements.View full textDownload full textKeywordsEllman method, Human serum antioxidants, Modified CUPRAC method, Protein thiols, Total antioxidant capacityRelated var addthis_config = { ui_cobrand: "Taylor & Francis Online", services_compact: "citeulike,netvibes,twitter,technorati,delicious,linkedin,facebook,stumbleupon,digg,google,more", pubid: "ra-4dff56cd6bb1830b" }; Add to shortlist Link Permalink http://dx.doi.org/10.1080/00032719.2011.653901
机译:由于总抗氧化剂容量(TAC)测量分析方法的不足,蛋白质最初是通过沉淀从人血清基质中分离出来的,未经测量,从而引起重要的“抗氧化剂缺口”。这项工作的目的是用改良的CUPric降低抗氧化能力(CUPRAC)方法测量血清的TAC,并确定血清蛋白(尤其是含硫醇的蛋白)对TAC的贡献。将CUPRAC结果与参考方法进行统计学比较,即ABTS(2,2′-叠氮基双(3-乙基苯并噻唑啉-6-磺酸),FRAP(三氧化三铁还原抗氧化能力)和Ellman硫醇测定法。三种不同的血清样品的吸光度与硫醇浓度以及吸光度与稀释血清(全血清,三氯乙酸(TCA)沉淀和再溶解的血清蛋白溶液以及TCA上清液馏分)的体积显示出优异的线性度和低截留率只能通过改进的CUPRAC方法获得最佳值。建议的方法将有助于表征源自蛋白质成分的血清TAC的``抗氧化剂缺口'',这在将来的抗氧化剂测量中不应忽略。查看全文下载全文关键字Ellman方法,人血清抗氧化剂,修改后的CUPRAC方法,蛋白硫醇,总抗氧化剂能力相关变量add add this_config = {ui_cobrand:“泰勒和弗朗西斯在线”,service_compact:“ citeulike,netvi bes,twitter,technorati,可口,linkedin,facebook,stumbleupon,digg,google,更多”,发布号:“ ra-4dff56cd6bb1830b”};添加到候选列表链接永久链接http://dx.doi.org/10.1080/00032719.2011.653901

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号