首页> 外文期刊>Analytical Chemistry >COMPREHENSIVE THREE-DIMNENSIONAL SEPARATION OF PEPTIDES USING SIZE EXCLUSION CHROMATOGRAPHY REVERSED PHASE LIQUID CHROMATOGRAPHY OPTICALLY GATED CAPILLARY ZONE ELECTROPHORESIS
【24h】

COMPREHENSIVE THREE-DIMNENSIONAL SEPARATION OF PEPTIDES USING SIZE EXCLUSION CHROMATOGRAPHY REVERSED PHASE LIQUID CHROMATOGRAPHY OPTICALLY GATED CAPILLARY ZONE ELECTROPHORESIS

机译:尺寸排阻色谱-反相液相色谱-电控毛细管区带电泳法对多肽的三维分离

获取原文
获取原文并翻译 | 示例
       

摘要

Multidimensional separation methods are attractive because of their potentially high peak capacities. Coupled-column systems in particular offer the advantages of online detection and automation. With the development of rapid two-dimensional (2D) analysis, it becomes possible to consider three-dimensional (3D) separation systems. In such a 3D system, effluent from a slow first dimension is repetitively sampled into a rapid 2D system. In the resultant data, each sample component has been subjected to three separative displacements, and the overall peak capacity is the product of that of each of the three dimensions. This paper demonstrates a comprehensive coupled-column 3D analysis of peptides. Size exclusion chromatography (SEC) is used as the first dimension to separate sample components by molecular weight, over an analysis time of several hours. The SEC effluent is repetitively sampled on-line into a rapid 2D reversed phase liquid chromatography/capillary zone electrophoresis (CZE) system with an analysis time of 7 min. Detection of sample zones is done only after the final CZE separation, by laser-induced fluorescence detection. Analysis data from this system consist of a series of 2D ''slices'' of the SEC effluent, which when stacked together give the 3D separation ''volume''.
机译:多维分离方法因其潜在的高峰容量而具有吸引力。耦合柱系统尤其具有在线检测和自动化的优势。随着快速二维(2D)分析的发展,考虑三维(3D)分离系统成为可能。在这样的3D系统中,缓慢的第一维流出物被重复采样到快速2D系统中。在结果数据中,每个样品成分都经历了三个分离位移,总峰容量是三个维度中每个维度的乘积。本文演示了对肽的全面偶联柱3D分析。在数小时的分析时间内,尺寸排阻色谱法(SEC)被用作第一维以分子量分离样品组分。将SEC废水在线重复采样到快速2D反相液相色谱/毛细管区带电泳(CZE)系统中,分析时间为7分钟。仅在最后的CZE分离之后,才通过激光诱导的荧光检测来完成对样品区域的检测。来自该系统的分析数据由SEC流出物的一系列2D“切片”组成,将它们堆叠在一起时可得到3D分离“体积”。

著录项

  • 来源
    《Analytical Chemistry》 |1995年第19期|p.3456-3463|共8页
  • 作者

    Moore AW; Jorgenson JW;

  • 作者单位

    Jorgenson JW, UNIV N CAROLINA, DEPT CHEM, CB 3290, CHAPEL HILL, NC 27599, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

  • 入库时间 2022-08-18 01:05:41

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号