首页> 外文期刊>Analytical Chemistry >QUANTITATIVE ENZYME-LINKED IMMUNOSORBENT ASSAY FOR DETERMINATION OF POLYCHLORINATED BIPHENYLS IN ENVIRONMENTAL SOIL AND SEDIMENT SAMPLES
【24h】

QUANTITATIVE ENZYME-LINKED IMMUNOSORBENT ASSAY FOR DETERMINATION OF POLYCHLORINATED BIPHENYLS IN ENVIRONMENTAL SOIL AND SEDIMENT SAMPLES

机译:定量酶联免疫吸附法测定环境土壤和沉积物中的多氯联苯

获取原文
获取原文并翻译 | 示例
           

摘要

An enzyme-linked immunosorbent assay (EIJSA) for the quantitative determination of Aroclors 1242, 1248, 1254, and 1260 in soil and sediments was developed and its performance compared with that of gas chromatography (GC), The detection limits for Aroclors 1242 and 1248 in soil are 10.5 and 9 ng/g, respectively, The assay linear dynamic range is 50-1333 ng/g, Cross-reactivity of the assay with 37 structurally related potential cocontaminants in environmental soil samples was examined; none of the chlorinated anisoles, benzenes, or phenols exhibited >3% cross-reactivity, with <0.1% cross-reactivity being the norm, Soil spike recoveries of 107% and 104% were obtained for Aroclors 1242 and 1248, respectively, for a spike level of 5 mg/kg, with corresponding relative standard deviations of 14% and 17%, One hundred forty-eight environmental soil, sediment, and paper pulp samples, obtained from two EPA listed Superfund sites, were analyzed by ELISA and standard GC methods. Samples were extracted for ELISA analysis by shaking with methanol, Additional extractions of the same samples were performed either with supercritical carbon dioxide or by Soxhlet extraction with methanol, ELISA results for both the supercritical fluid and the Soxhlet extracts were in close agreement with the GC results, while the ELISA results for the methanol shake extracts were not, The data for the environmental samples demonstrated the capability of the ELISA to provide accurate results and reinforced the dependence of any detection method, including ELISA, on appropriate extraction procedures.
机译:建立了一种酶联免疫吸附测定法(EIJSA),用于定量测定土壤和沉积物中的Aroclors 1242、1248、1254和1260,并与气相色谱(GC)进行了比较.Aroclors 1242和1248的检出限在土壤中的含量分别为10.5和9 ng / g,测定线性动态范围为50-1333 ng / g,检查了该测定与环境土壤样​​品中37种与结构相关的潜在协同污染物的交叉反应性;氯代茴香醚,苯或苯酚均没有表现出> 3%的交叉反应性,<0.1%的交叉反应性是常态,Aroclors 1242和1248的土壤峰值回收率分别为107%和104%。加标水平为5 mg / kg,相应的相对标准偏差为14%和17%,通过ELISA和标准GC分析了从EPA列出的两个超级基金站点中获得的148个环境土壤,沉积物和纸浆样品方法。通过与甲醇一起摇动来提取样品进行ELISA分析;用超临界二氧化碳或甲醇进行索氏提取进行相同样品的其他提取,超临界流体和索氏提取物的ELISA结果与GC结果非常吻合,虽然没有测定甲醇奶昔提取物的ELISA结果,但环境样品的数据证明了ELISA能够提供准确的结果,并加强了包括ELISA在内的任何检测方法对适当提取程序的依赖性。

著录项

  • 来源
    《Analytical Chemistry》 |1996年第1期|p.162-169|共8页
  • 作者

    Johnson JC; Vanemon JM;

  • 作者单位

    Johnson JC, US EPA, NATL EXPOSURE RES LAB, CHARACTERIZAT RES DIV, LAS VEGAS, NV 89119, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号