首页> 外文期刊>Analytical and Bioanalytical Chemistry >Improved efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) from the National Institute of Standards and Technology (NIST) Standard Reference Material Diesel Particulate Matter (SRM 2975) using accelerated solvent extraction
【24h】

Improved efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) from the National Institute of Standards and Technology (NIST) Standard Reference Material Diesel Particulate Matter (SRM 2975) using accelerated solvent extraction

机译:使用加速溶剂萃取,从美国国家标准技术研究院(NIST)标准参考物质柴油颗粒物(SRM 2975)中提高了多环芳烃(PAH)的萃取效率

获取原文
获取原文并翻译 | 示例
           

摘要

The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.
机译:使用加速溶剂萃取(ASE)和二氯甲烷进行了研究,研究了从标准参考材料柴油颗粒物(SRM 2975)中提取分子量为252、276、278、300和302 Da的多环芳烃(PAH)的效率,甲苯,甲醇,以及甲苯和甲醇的混合物。在最大仪器设置(200°C,20.7 MPa和五个萃取循环)下,使用甲苯/甲醇(9:1,v / v)萃取SRM 2975,萃取时间为30分钟,导致以下浓度的升高与美国国家标准技术研究所(NIST)报告的认证浓度和参考浓度相比:苯并[b]荧蒽为46%;苯并[k]荧蒽,137%;苯并[e] py,103%;苯并[a] py 1,570%; 37%;茚并[1,2,3-cd] py,41%;苯并perper,163%;和co烯361%。以下PAHs的浓度与NIST分配的参考值相当:茚并[1,2,3-cd]荧蒽,苯并[a,h]蒽和race烯。二苯并[a,e] -py的测量浓度低于NIST报告的信息值。还报告了SRM 2975中其他高度致癌的PAH(二苯并[a,l] ,、二苯并[a,i] and和二苯并[a,h] re)的测量浓度。使用优化的ASE方法和与NIST在SRM 2975中分配PAH浓度所使用的条件相似的条件进行的测量比较表明,本研究中获得的较高值与从柴油机颗粒材料中更完全地提取PAHs有关。再次萃取颗粒样品表明,氘化内标比天然PAH更容易回收,这可以解释NIST报道的较低值。研究中获得的分析结果表明,从SRM 2975中有效提取多环芳烃是准确测定此标准参考材料中高分子量多环芳烃的关键要求,并且优化提取条件对于避免低估苯酚含量至关重要。 PAH浓度。该要求与人类致癌物苯并[a] py特别相关,后者通常被用作PAH混合物带来致癌风险的指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号