首页> 外文期刊>Analytical and Bioanalytical Chemistry >Rapid quantification of tilidine, nortilidine, and bisnortilidine in urine by automated online SPE-LC-MS/MS
【24h】

Rapid quantification of tilidine, nortilidine, and bisnortilidine in urine by automated online SPE-LC-MS/MS

机译:通过自动在线SPE-LC-MS / MS快速定量尿液中的替尼丁,去甲替丁和双去甲替丁

获取原文
获取原文并翻译 | 示例
           

摘要

The opioid tilidine is a prodrug which is hepatically metabolized to active nortilidine and bisnortilidine. Due to the increasing abuse of tilidine by drug users and the lack of a specific immunoassay, we developed an analytical method for the quantification of tilidine, nortilidine, and bisnortilidine in urine suitable for screening. In a following step, this method was used to establish data on excretion kinetics of the substances in order to evaluate the time window of detection after a single oral dose of tilidinealoxone and also was applied to authentic urine samples from correctional facilities. Urine samples were mixed with internal standard solution and extracted on a weak cation exchanger at pH 6 using a Symbiosis Pico system. The chromatographic separation was achieved within a 3.5-min run time on a Phenylhexyl column (50 × 2.0 mm, 5 μm) via gradient elution (methanol and 0.2% formic acid) at a flow rate of 0.50 mL/min. The ESI-MS/MS was performed on a QTrap 3,200 in positive multiple reaction monitoring mode using two mass transitions per analyte. Validating the method resulted in a lower limit of quantification of 1.0 μg/L followed by a linear calibration range to 100 μg/L for each analyte (r 2 > 0.99). The analytical method allowed the detection of a single dose of a commercially available tilidine solution up to 7 days after administration. Using this highly sensitive method, 55 of 3,665 urine samples were tested positive.
机译:阿片样物质的替丁啶是一种前药,它在肝脏中被代谢为活性的鸟丁啶和双甲蝶啶。由于吸毒者对替丁的滥用不断增加,并且缺乏特异性的免疫测定方法,我们开发了一种定量分析尿液中的替丁,去甲替丁和双去甲替丁的分析方法。在接下来的步骤中,此方法用于建立有关物质排泄动力学的数据,以便评估单次口服蒂替丁/纳洛酮后的检测时间窗,并且还应用于来自矫正机构的真实尿液样本。将尿液样品与内标溶液混合,并使用Symbiosis Pico系统在pH 6的弱阳离子交换剂上萃取。通过梯度洗脱(甲醇和0.2%甲酸)以0.50 mL / min的流速在苯基己基色谱柱(50×2.0 mm,5μm)上在3.5分钟的运行时间内完成色谱分离。 ESI-MS / MS在QTrap 3,200上以正多反应监测模式执行,每个分析物使用两次质量跃迁。验证方法后,每种分析物的定量下限为1.0μg/ L,然后线性校准范围为100μg/ L(r 2

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号