Implementation of three-phase power factor correction circuit with less power switches and current sensors

机译:用更少的功率开关和电流传感器实现三相功率因数校正电路

获取原文
获取原文并翻译 | 示例
       

摘要

A three-phase ac to dc converter employing a new control scheme is presented. Only four power switches and two current sensors are required in this system. By using the proposed control scheme, just two of the switches are active to approach the desired waveform at any timer, hence the switching numbers can be reduced, compared with the conventional six switches converter. Furthermore, the local average method is presented to verify that the instantaneous power between ac source and dc source is balanced. Finally, simulated and experimental results are presented to verify the characteristics of unity power factor, sinusoidal input current, and bidirectional power flow capability.
机译:提出了采用新控制方案的三相交流到直流转换器。该系统仅需要四个电源开关和两个电流传感器。通过使用所提出的控制方案,只有两个开关处于活动状态以在任何计时器处接近所需波形,因此与常规的六个开关转换器相比,可以减少开关数量。此外,提出了局部平均法以验证交流电源和直流电源之间的瞬时功率是否平衡。最后,通过仿真和实验结果验证了单位功率因数,正弦输入电流和双向潮流能力。