Link-to-column connections in steel eccentrically braced frames must sustain large moments and shear forces to support link rotation. Recent studies showed that link-to-column connections are prone to failure at low drift levels due to their susceptibility to fracture at the link flange-to-column connections. The most promising method to overcome this problem is to utilize reduced beam section in link, in order to keep away stress concentration from the link ends. In this investigation, the application of reduced beam section in long link beams is studied experimentally. Two full-scale specimens with different reduced beam section locations are constructed and tested under cyclic loading. In one specimen, reduced beam section is placed at both ends of the link beam; and in the other specimen, reduced beam section is solely placed at the link end which is near the column. The results show that both specimens have satisfied the seismic code requirements for the link inelastic rotation, which in turn leads to improvement in seismic performance.
机译:钢制偏心支撑框架中的链节至圆柱连接必须承受较大的力矩和剪切力,以支持链节的旋转。最近的研究表明,链节到柱的连接由于在链节节到柱的连接处容易断裂而易于在低漂移水平下失效。克服此问题的最有前途的方法是在连杆中使用减小的梁截面,以使应力集中在连杆的两端。在这项研究中,实验研究了减小的截面截面在长连接梁中的应用。构造了两个具有不同减小的梁截面位置的满刻度样品,并在循环载荷下进行了测试。在一个试样中,减小的梁截面放置在连接梁的两端。在另一个试样中,减小的梁截面仅放置在靠近圆柱的连杆端。结果表明,两个标本都满足链节非弹性旋转的抗震规范要求,从而提高了抗震性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号