We carried out an experimental investigation to study the influence of concrete carbonation on the natural frequency of simply supported reinforced concrete beams. A total of 10 reinforced concrete test beams and 12 concrete-carbonation test specimens were subjected to different accelerated carbonation stages for 0, 7, 14, 21, and 28 days. Modal tests were performed on reinforced concrete test beams after the accelerated carbonation stages. In order to reduce the effect of other factors on the modal tests, constant temperature, relative humidity, and boundary conditions of the test beams were maintained in the experimental process. The experimental results show a trend of the natural frequencies of reinforced concrete test beams to decrease with the increase in concrete-carbonation depths. With statistical analyses of experimental data, this study established the relationship between concrete-carbonation depths and natural frequencies. Fitting lines for the drop in natural frequencies and carbonation depths are obtained for the first four modal frequencies. Based on the analysis of the physicochemical processes of concrete carbonation, the main reason behind the drop in natural frequencies is the increase in mass after concrete carbonation. The percentage composition of increase in mass after complete carbonation is obtained based on the analysis of the physicochemical process. This analysis demonstrates part of the reason for the drop in natural frequencies and proves that the experimental results are reliable and credible. This study provides further insight into the use of modal parameters to assess damage in concrete structures in structural health monitoring.
机译:我们进行了一项实验研究,以研究混凝土碳化对简支钢筋混凝土梁固有频率的影响。总共10个钢筋混凝土测试梁和12个混凝土碳化试验样品分别经历了0、7、14、21和28天的不同加速碳化阶段。在加速碳化阶段之后,对钢筋混凝土测试梁进行了模态测试。为了减少其他因素对模态测试的影响,在实验过程中保持了恒温,相对湿度和测试梁的边界条件。实验结果表明,随着混凝土碳化深度的增加,钢筋混凝土试验梁的固有频率有减小的趋势。通过对实验数据的统计分析,本研究建立了混凝土碳化深度与自然频率之间的关系。对于前四个模态频率,获得了自然频率和碳化深度下降的拟合线。根据对混凝土碳化的理化过程的分析,自然频率下降的主要原因是混凝土碳化后质量的增加。基于理化过程的分析,获得了完全碳酸化后质量增加的百分比组成。该分析证明了自然频率下降的部分原因,并证明了实验结果是可靠且可信的。这项研究提供了对模态参数在结构健康监测中评估混凝土结构损伤的进一步了解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号