...
首页> 外文期刊>Advances in Engineering Software >Optimal selections of orthodontic mini-implant diameter and length by biomechanical consideration: A three-dimensional finite element analysis
【24h】

Optimal selections of orthodontic mini-implant diameter and length by biomechanical consideration: A three-dimensional finite element analysis

机译:基于生物力学的正畸微型种植体直径和长度的最佳选择:三维有限元分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A finite element analysis was carried out to evaluate continuous and simultaneous variations of orthodontic mini-implant diameter and length, and to identify their optimal ranges in the maxillary posterior region. Within the ranges of diameter from 1.0 mm to 2.0 mm and the length from 6.0 mm to 16.0 mm, our results showed that the increases of the diameter and length reduced the maximum equivalent stresses in cortical, cancellous bones and mini-implant by 80.94%, 91.84% and 86.11%, respectively, and the maximum displacement in the mini-implant by 81.29%. When the diameter exceeded 1.5 mm and the length exceeded 11.0 mm, the mini-implant achieved the best stability and the lowest levels of stress and displacement. At the similar increment, the change in the diameter was more effective than the change of length in reducing bone-implant complex stresses and enhancing mini-implant stability. Diameter exceeding 1.5 mm in combination with the longest length in safety range were the optimal biomechanical choice for the maxillary posterior region in a screwed orthodontic mini-implant.
机译:进行了有限元分析,以评估正畸微型种植体直径和长度的连续和同时变化,并确定其在上颌后牙区域的最佳范围。我们的结果表明,在直径从1.0毫米到2.0毫米,长度从6.0毫米到16.0毫米的范围内,皮质,松质骨和微型植入物的最大等效应力降低了80.94%,微型植入物的最大位移分别为91.84%和86.11%,最大位移为81.29%。当直径超过1.5毫米,长度超过11.0毫米时,微型植入物获得了最佳的稳定性以及最低的应力和位移水平。以相似的增量,在减小骨植入物复合应力和增强微型植入物稳定性方面,直径变化比长度变化更有效。直径超过1.5毫米且在安全范围内的最长长度相结合,是螺钉式正畸微型种植体上颌后部区域的最佳生物力学选择。

著录项

  • 来源
    《Advances in Engineering Software》 |2009年第11期|1124-1130|共7页
  • 作者单位

    Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, PR China;

    Department of Oral and Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, PR China;

    Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, PR China;

    Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, PR China;

    Department of Oral and Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, PR China;

    Department of Orthodontics, School of Stomatology, The Fourth Military Medical University, 145 West Changle Rd., Xi'an 710032, PR China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    mini-implant; anchorage; finite element analysis; diameter; length;

    机译:微型植入物锚地有限元分析;直径;长度;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号