首页> 外文期刊>Advances in building energy research >Dynamic heat transfer analysis of the wall implanted with heat pipes in summer
【24h】

Dynamic heat transfer analysis of the wall implanted with heat pipes in summer

机译:夏季热管植入墙体的动态传热分析

获取原文
获取原文并翻译 | 示例
           

摘要

The wall implanted with heat pipes overcomes the contradiction between building energy efficiency and wall insulation by transferring the radiant heat from the sun to room during heating season and transferring the heat from room to outside during cooling season. This paper establishes the dynamic thermal transfer model of wall implanted with heat pipes (WIHP) in summer and simulates the dynamic heat transfer process. As revealed by the results, WIHP works 6.2 hours per day on average during the cold season. The rise in the average heat transfer from indoor to outdoor was measured to be 16.66 W/m~2, and the surface temperature was found to drop by 2°C on average as compared to the conventional wall. In comparison, the new wall exhibited an improved capability in terms of heat dissipation, indicating that it was effective in lowering energy consumption and boosting indoor thermal comfort.
机译:植入热管的壁克服了通过将辐射热量从太阳转移到加热季节,在冷却季期间将热量从房间转移到外部的空间来克服了建筑能效和壁绝缘之间的矛盾。本文在夏季建立了植入热管(WIHP)壁的动态热转印模型,并模拟动态传热过程。正如结果所揭示的那样,在寒冷的季节期间,WIHP每天每天工作6.2小时。测量来自室内到室外的平均传热的升高为16.66W / m〜2,并且与常规壁相比,发现表面温度平均下降2℃。相比之下,新墙在散热方面表现出改善的能力,表明它在降低能耗和提高室内热舒适度方面是有效的。