首页> 外文期刊>ACI Structural Journal >Thermal Behavior of Fire-Exposed Concrete Slabs Reinforced with Fiber-Reinforced Polymer Bars
【24h】

Thermal Behavior of Fire-Exposed Concrete Slabs Reinforced with Fiber-Reinforced Polymer Bars

机译:纤维增强聚合物棒增强受火混凝土板的热性能

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Experimental studies were carried out to investigate the thermal performance of concrete slabs reinforced with carbon and glass fiber-reinforced polymer (FRP) bars in fire. The effect of varying a number of slab parameters was studied to establish those that are critical for the fire resistance of these members. Test parameters in the experimental study included the reinforcement type, the slab thickness, the concrete cover thickness to the reinforcement, the aggregate type, and the effectiveness of supplemental fire insulation. Results indicated that the qualitative and heat transfer behavior of concrete slabs reinforced with FRP bars was similar to that of slabs reinforced with steel reinforcing bars. The thickness of the concrete cover to the reinforcement and the type of reinforcement were found to be key parameters that influence the fire resistance of FRP-reinforced concrete slabs.
机译:进行了实验研究,以研究碳纤维和玻璃纤维增​​强聚合物(FRP)钢筋在火灾中的混凝土板的热性能。研究了改变许多平板参数的影响,以建立对于这些构件的耐火性至关重要的参数。实验研究中的测试参数包括钢筋类型,平板厚度,钢筋混凝土覆盖层厚度,骨料类型以及辅助防火隔热的有效性。结果表明,FRP筋混凝土板的定性和传热性能与钢筋混凝土板的定性和传热性能相似。发现覆盖钢筋的混凝土覆盖层的厚度和钢筋的类型是影响FRP钢筋混凝土板耐火性的关键参数。