首页> 美国卫生研究院文献>Springer Open Choice >Development of a microfluidic confocal fluorescence detection system for the hyphenation of nano-LC to on-line biochemical assays
【2h】

Development of a microfluidic confocal fluorescence detection system for the hyphenation of nano-LC to on-line biochemical assays

机译:开发用于纳米LC联用到在线生化分析的微流共聚焦荧光检测系统

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

One way to profile complex mixtures for receptor affinity is to couple liquid chromatography (LC) on-line to biochemical detection (BCD). A drawback of this hyphenated screening approach is the relatively high consumption of sample, receptor protein and (fluorescently labeled) tracer ligand. Here, we worked toward minimization of sample and reagent consumption, by coupling nano-LC on-line to a light-emitting diode (LED) based capillary confocal fluorescence detection system capable of on-line BCD with low-flow rates. In this fluorescence detection system, a capillary with an extended light path (bubble cell) was used as a detection cell in order to enhance sensitivity. The technology was applied to a fluorescent enhancement bioassay for the acetylcholine binding protein, a structural analog of the extracellular ligand-binding domain of neuronal nicotinic acetylcholine receptors. In the miniaturized setup, the sensitive and low void volume LED-induced confocal fluorescence detection system operated in flow injection analysis mode allowing the measurement of IC50 values, which were comparable with those measured by a conventional plate reader bioassay. The current setup uses 50 nL as injection volume with a carrier flow rate of 400 nL/min. Finally, coupling of the detection system to gradient reversed-phase nano-LC allowed analysis of mixtures in order to identify the bioactive compounds present by injecting 10 nL of each mixture.Electronic supplementary materialThe online version of this article (doi:10.1007/s00216-010-4210-x) contains supplementary material, which is available to authorized users.
机译:分析复杂混合物的受体亲和力的一种方法是将液相色谱(LC)在线连接到生化检测(BCD)。这种联用筛选方法的缺点是样品,受体蛋白和(荧光标记的)示踪配体的消耗量相对较高。在这里,我们通过将纳米LC在线耦合到基于发光二极管(LED)的毛细管共聚焦荧光检测系统,以使样品和试剂消耗最小化,该系统能够以低流速在线BCD。在该荧光检测系统中,为了提高灵敏度,使用了光路延长的毛细管(气泡池)作为检测池。该技术已应用于乙酰胆碱结合蛋白的荧光增强生物测定,乙酰胆碱结合蛋白是神经元烟碱乙酰胆碱受体的细胞外配体结合域的结构类似物。在小型化设置中,灵敏且低空隙体积的LED诱导的共聚焦荧光检测系统以流动注射分析模式运行,可以测量IC50值,该值可与传统的酶标仪生物测定法相媲美。当前设置使用50 nL作为进样量,载流子流速为400 nL / min。最后,将检测系统与梯度反相纳米LC偶联,可以对混合物进行分析,以便通过向每种混合物中注入10 nL的混合物来鉴定存在的生物活性化合物。电子补充材料本文的在线版本(doi:10.1007 / s00216- 010-4210-x)包含补充材料,授权用户可以使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号