The development of lens-antenna-coupled aluminum-based microwave kinetic inductance detectors (MKIDs) and on-chip spectrometers needs a dedicated cryogenic setup to measure the beam patterns of the lens-antenna system over a large angular throughput and broad frequency range. This requires a careful design since the MKID has to be cooled to temperatures below 300mK to operate effectively. We developed such a cryostat with a large opening angle θ=±37.8 and an optical access with a low-pass edge at 950GHz. The system is based upon a commercial pulse tube cooled 3 K system with a 4He3He sorption cooler to allow base temperatures below 300mK. A careful study of the spectral and geometric throughput was performed to minimize thermal loading on the cold stage, allowing a base temperature of 265mK. Radio-transparent multi-layer-insulation was employed as a recent development in filter technology to efficiently block near-infrared radiation.
机译:透镜天线耦合的铝基微波动电感检测器(MKID)和片上光谱仪的开发需要专用的低温设置,以在大角度通量和宽频率范围内测量透镜天线系统的波束方向图。由于必须将MKID冷却到低于 300 mK 即可有效运行。我们开发了一种具有大张角的低温恒温器。 θ = ± 37 8 ,并且在 950 GHz 。该系统基于带有 < mrow> 4 He 3 He 吸附冷却器,以使基本温度低于 300 mK 。对光谱和几何通量进行了仔细的研究,以最大程度地减少冷台上的热负荷,从而允许基本温度为 265 mK 。无线电透明多层绝缘被用作滤波器技术的最新发展,以有效地阻挡近红外辐射。