首页> 美国卫生研究院文献>PLoS Clinical Trials >Normative 3D opto-electronic stereo-photogrammetric sagittal alignment parameters in a young healthy adult population
【2h】

Normative 3D opto-electronic stereo-photogrammetric sagittal alignment parameters in a young healthy adult population

机译:年轻健康成年人群中的标准3D光电立体摄影测量矢状位对准参数

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper describes and presents a stable and reliable set of stereo-photogrammetric normative data for global and spino-pelvic sagittal alignment, as a proven reference system for evaluating/measuring a fully unconstrained natural upright neutral standing attitude in a young healthy adult population. The methodological features described in this article will enable future studies to replicate and/or directly compare a wide range of different postural tests and/or sagittal alignment assessment procedures including the study of sagittal spine shape variations occurring during gait performance. To date, the quantitative evaluation of adult spinal deformity (ASD) has been mainly confined to the X-ray imaging approach and, more recently, to 3D X-ray reconstruction. Within the existing evaluation framework an opportunity exists for an additional approach: a quantitative evaluation procedure which is easy, accurate, relatively speedy and non-ionising, in order to monitor and track the progress of patients in the areas of both surgical and non-surgical treatment. The resources and methodology described in this paper have been proven to meet all these criteria. They have enabled full 3D posture (including 3D spine shape and sagittal alignment of the skeleton) to be consistently and successfully measured in adult volunteers. All the measurement/evaluation procedures and outcomes carried out were based entirely on the new non-ionising 3D opto-electronic stereo-photogrammetric approach described in this article. The protocol for this methodology was based on a standard set of 27 pre-selected anatomical “landmarks” on the human body, providing standard reference points for observation and measurement. A total of 124 healthy subjects were successfully assessed and, for each subject, 27 individual markers were applied to the corresponding locations on his/her body. Statistical tests to investigate gender differences were also carried out. Descriptive statistics are provided for all 15 of the spino-pelvic parameters under consideration. Results indicated significant differences between genders in five sets of parameters: Kyphosis tilt, Head tilt, Pelvic tilt, Spino-pelvic angle and T1-pelvic angle. The data also demonstrate a high degree of congruity with results obtained using the X-ray method, as evidenced by the existing literature in the field. In summary, the current study presents a new stereo-photogrammetric opto-electronic technology which can be used successfully for ASD evaluation and introduces a comprehensive set of normative data analogous to those proposed in X-ray analysis for sagittal spino-pelvic and total body alignment.
机译:本文描述并提出了一套稳定可靠的立体摄影规范数据,用于整体和脊柱骨矢状位对准,作为评估/测量年轻健康成年人群中完全不受约束的自然直立中立站立态度的可靠参考系统。本文所述的方法学特征将使未来的研究能够复制和/或直接比较各种不同的姿势测试和/或矢状面对准评估程序,包括研究步态运动过程中发生的矢状脊柱形状变化。迄今为止,对成人脊柱畸形(ASD)的定量评估主要局限于X射线成像方法,最近还局限于3D X射线重建。在现有的评估框架内,有机会采用其他方法:简便,准确,相对快速且不电离的定量评估程序,以便在手术和非手术领域监测和跟踪患者的进展治疗。本文中描述的资源和方法已被证明可以满足所有这些标准。他们使完整的3D姿势(包括3D脊柱形状和骨骼的矢状面对准)得以一致且成功地在成人志愿者中进行了测量。所有执行的测量/评估程序和结果均完全基于本文所述的新型非电离3D光电立体摄影测量方法。该方法的协议基于人体上27个预先选择的解剖学“地标”的标准集合,为观察和测量提供了标准参考点。总共成功评估了124位健康受试者,对于每个受试者,将27个单独的标记物应用于他/她身体上的相应位置。还进行了统计检验以调查性别差异。提供了所考虑的所有15个脊柱骨盆参数的描述性统计数据。结果表明性别在五组参数中存在显着差异:后凸畸形,头部倾斜,骨盆倾斜,脊柱骨盆角和T1-骨盆角。数据也显示出与使用X射线方法获得的结果高度一致,这一点已得到本领域现有文献的证明。总而言之,当前的研究提出了一种可以成功用于ASD评估的新的立体摄影测量光电技术,并介绍了一套与X射线分析中提出的用于矢状脊柱骨盆和全身对准的拟议数据类似的一整套规范数据。 。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号