首页> 美国卫生研究院文献>PLoS Clinical Trials >Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices
【2h】

Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices

机译:心力衰竭患者与设备之间达成协议的6分钟步行测试期间心率变异性分析的可重复性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86<CCC<0.99] based on Holter at rest, during 6MW and recovery. At higher rates, a small effect in increasing differences between Holter and Polar in R-R intervals was observed. In conclusion, our study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.
机译:心率变异性(HRV)分析是评估自主神经系统异常功能并预测心力衰竭(HF)患者心脏事件的有用方法。使用心率监测仪进行的HRV测量已通过心电图仪在健康受试者中得到验证,但在HF患者中并未得到验证。我们使用心率监测器(PolarS810i)和便携式心电图仪(称为Holter)对50例HF患者(平均年龄59岁,NYHA)进行了两个连续的六分钟步行测试(6MW),相距60分钟的HRV的重现性II,左心室射血分数〜35%)。使用配对t检验或Wilcoxon符号秩检验对每种设备的可重复性进行了分析。此外,我们使用静止相关系数(CCC),95%置信区间和Bland-Altman图,根据静止,6MW以及恢复期间的HRV指数评估了两种设备之间的一致性。在静止状态下使用Holter和PolarS810i可重现HRV分析的重测结果,但在恢复过程中则不可重现。在第二个6MW中,患者的rMSSD和步行距离显着增加。基于Holter在6MW和恢复期间的静止状态,PolarS810i测量值具有非常高的一致性相关性[0.86

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号