首页> 美国卫生研究院文献>PLoS Clinical Trials >Response-Related Potentials during Semantic Priming: The Effect of a Speeded Button Response Task on ERPs
【2h】

Response-Related Potentials during Semantic Priming: The Effect of a Speeded Button Response Task on ERPs

机译:语义启动过程中与响应相关的电位:快速按钮响应任务对ERP的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study examines the influence of a button response task on the event-related potential (ERP) in a semantic priming experiment. Of particular interest is the N400 component. In many semantic priming studies, subjects are asked to respond to a stimulus as fast and accurately as possible by pressing a button. Response time (RT) is recorded in parallel with an electroencephalogram (EEG) for ERP analysis. In this case, the response occurs in the time window used for ERP analysis and response-related components may overlap with stimulus-locked ones such as the N400. This has led to a recommendation against such a design, although the issue has not been explored in depth. Since studies keep being published that disregard this issue, a more detailed examination of influence of response-related potentials on the ERP is needed. Two experiments were performed in which subjects pressed one of two buttons with their dominant hand in response to word-pairs with varying association strength (AS), indicating a personal judgement of association between the two words. In the first experiment, subjects were instructed to respond as fast and accurately as possible. In the second experiment, subjects delayed their button response to enforce a one second interval between the onset of the target word and the button response. Results show that in the first experiment a P3 component and motor-related potentials (MRPs) overlap with the N400 component, which can cause a misinterpretation of the latter. In order to study the N400 component, the button response should be delayed to avoid contamination of the ERP with response-related components.
机译:这项研究在语义启动实验中检查了按钮响应任务对事件相关电位(ERP)的影响。 N400组件特别受关注。在许多语义启动研究中,要求受试者通过按下按钮来尽可能快而准确地响应刺激。响应时间(RT)与脑电图(EEG)并行记录,用于ERP分析。在这种情况下,响应发生在用于ERP分析的时间窗口中,并且与响应相关的组件可能与刺激锁定的组件(例如N400)重叠。尽管尚未对此问题进行深入探讨,但仍提出了反对这种设计的建议。由于不断发表的研究忽略了这个问题,因此需要对响应相关电位对ERP的影响进行更详细的检查。进行了两个实验,其中受试者响应于具有变化的关联强度(AS)的单词对,用惯用的手按下两个按钮之一,表示对这两个单词之间关联的个人判断。在第一个实验中,指示受试者尽可能快速准确地做出反应。在第二个实验中,对象延迟了他们的按钮响应,以在目标单词的开始和按钮响应之间强制间隔一秒钟。结果表明,在第一个实验中,P3组件和运动相关电位(MRP)与N400组件重叠,这可能导致对N400组件的误解。为了研究N400组件,应该延迟按钮响应,以避免响应相关组件污染ERP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号