首页> 美国卫生研究院文献>PLoS Clinical Trials >Reliability of Serum Metabolite Concentrations over a 4-Month Period Using a Targeted Metabolomic Approach
【2h】

Reliability of Serum Metabolite Concentrations over a 4-Month Period Using a Targeted Metabolomic Approach

机译:使用目标代谢组学方法研究4个月内血清代谢物浓度的可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Metabolomics is a promising tool for discovery of novel biomarkers of chronic disease risk in prospective epidemiologic studies. We investigated the between- and within-person variation of the concentrations of 163 serum metabolites over a period of 4 months to evaluate the metabolite reliability expressed by the intraclass-correlation coefficient (ICC: the ratio of between-person variance and total variance). The analyses were performed with the BIOCRATES AbsoluteIDQ™ targeted metabolomics technology, including acylcarnitines, amino acids, glycerophospholipids, sphingolipids and hexose in 100 healthy individuals from the European Prospective Investigation into Cancer and Nutrition (EPIC)-Potsdam study who had provided two fasting blood samples 4 months apart. Overall, serum reliability of metabolites over a 4-month period was good. The median ICC of the 163 metabolites was 0.57. The highest ICC was observed for hydroxysphingomyelin C14:1 (ICC = 0.85) and the lowest was found for acylcarnitine C3:1 (ICC = 0). Reliability was high for hexose (ICC = 0.76), sphingolipids (median ICC = 0.66; range: 0.24–0.85), amino acids (median ICC = 0.58; range: 0.41–0.72) and glycerophospholipids (median ICC = 0.58; range: 0.03–0.81). Among acylcarnitines, reliability of short and medium chain saturated compounds was good to excellent (ICC range: 0.50–0.81). Serum reliability was lower for most hydroxyacylcarnitines and monounsaturated acylcarnitines (ICC range: 0.11–0.45 and 0.00–0.63, respectively). For most of the metabolites a single measurement may be sufficient for risk assessment in epidemiologic studies with healthy subjects.
机译:代谢组学是在前瞻性流行病学研究中发现慢性疾病风险的新型生物标志物的有前途的工具。我们调查了4个月内163种血清代谢产物浓度在人与人之间的变化,以评估由组内相关系数(ICC:人际变异与总变异之比)表示的代谢物可靠性。使用BIOCRATES AbsoluteIDQ™靶向代谢组学技术进行了分析,该技术包括100例来自欧洲癌症与营养前瞻性研究(EPIC)-波茨坦的健康人的酰基肉碱,氨基酸,甘油磷脂,鞘脂和己糖,他们提供了两个禁食的血液样本相隔4个月。总体而言,代谢产物在4个月内的血清可靠性良好。 163种代谢物的平均ICC为0.57。羟基鞘磷脂C14:1的ICC最高(ICC = 0.85),酰基肉碱C3:1的ICC最低(ICC = 0)。己糖(ICC = 0.76),鞘脂(ICC = 0.66;范围:0.24-0.85),氨基酸(ICC = 0.58;范围:0.41-0.72)和甘油磷脂(ICC = 0.58;范围:0.03)的可靠性很高–0.81)。在酰基肉碱中,短链和中链饱和化合物的可靠性好至极好(ICC范围:0.50–0.81)。大多数羟酰基肉碱和单不饱和酰基肉碱的血清可靠性较低(ICC范围分别为0.11-0.45和0.00-0.63)。对于大多数代谢物,在健康受试者的流行病学研究中,单个测量值可能足以评估风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号