The increasing interest of curdlan oligosaccharides (COS) in medicine and plant protection fields implies a necessity to identify and quantify this product. In the present study, an efficient and sensitive analytical method based on high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) was established for the simultaneous separation and determination of D-glucose and ß-1,3-linked COS ranging from (COS)2 to (COS)6 within 20 min. Detection limits were 0.01 to 0.03 mg/L. The optimized assay was performed on a CarboPac-PA100 analytical column (4 mm × 250 mm) using isocratic elution with water−0.2 M sodium hydroxide−0.5 M sodium acetate mixture (50 : 30 : 20, v/v/v) as the mobile phase at a flow rate of 0.8 mL/min. Regression equations indicated a good linear relationship (R2 = 0.9992–1.0000, n = 6) within the test ranges. Quality parameters including precision and accuracy were fully validated and found to be satisfactory. More important, the regression of natural logarithm values of retention times (log10 RT) versus the degree polymerization (DP), as well as the slope coefficient of each COS's linear equation versus the corresponding DP, fitted a linear relationship well. These inherent linear relationships could provide valuable information to tentatively identify and quantify the COS even with the DP more than 6 without authentic standard. Furthermore, when the log10 RT was plotted against log10 flow rate for each COS, a perfect linear relationship was also observed.
机译:凝胶多糖(COS)在医学和植物保护领域的兴趣日益浓厚,这意味着有必要鉴定和定量该产品。在本研究中,建立了一种基于高效阴离子交换色谱-脉冲安培检测(HPAEC-PAD)的高效灵敏分析方法,用于同时分离和测定D-葡萄糖和ß-1,3-连锁COS范围在20分钟内从(COS)2到(COS)6。检出限为0.01〜0.03μmg/ L。优化分析是在CarboPac-PA100分析柱(4 mm××250)mm)上进行的,等度洗脱使用水-0.2 M氢氧化钠-0.5 M乙酸钠混合物(50:30:20,v / v / v)。流动相,流速为0.8 mL / min。回归方程表明在测试范围内具有良好的线性关系(R 2 = 0.9992–1.0000,n = 6)。包括精度和准确性在内的质量参数已得到充分验证,并且令人满意。更重要的是,保留时间的自然对数值(log10 RT)对聚合度(DP)的回归,以及每个COS线性方程对相应的DP的斜率系数,都很好地拟合了线性关系。这些固有的线性关系可以提供有价值的信息,即使在DP大于6且没有真实标准的情况下,也可以初步识别和量化COS。此外,当针对每个COS将log10 RT与log10流量作图时,也观察到了完美的线性关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号