摘要

A fast, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was validated and then the levels of cortisol and cortisone from sera of healthy adults were determined by the LC-MS/MS method. One hundred μL of serum sample was directly extracted by adding 2 mL ethyl acetate, followed by chromatographic separation on a C18 column with a mobile phase consisting of 5 mM ammonium acetate and methanol (25 : 75, v/v). The precision, accuracy, and average recovery of the method were 1.5–5.3%, 95.4–102.5%, and 96.4% for cortisol, and 1.9–6.0%, 89.2–98.8%, and 79.9% for cortisone, respectively. The method was linear from 1.0 to 500.0 ng/mL (r2 = 0.999) for cortisol and 2.5 to 100.0 ng/mL (r2 = 0.998) for cortisone. The limits of detection (LOD) and quantification (LOQ) were 0.2 and 1.0 ng/mL for cortisol, and 1.0 and 2.5 ng/mL for cortisone, respectively. The average cortisol concentration (133.9 ± 63.7 ng/mL) of samples collected between 9:00 and 11:00 a.m. was higher approximately 4.4 times than that of cortisone (30.5 ± 10.7 ng/mL) (P < 0.0001). The average cortisone/cortisol ratio was 0.225. Therefore, the LC-MS/MS method may be useful for the diagnosis of some adrenal diseases and the assessment of 11β-hydroxysteroid dehydrogenase (11β-HSD) activity in clinical laboratories.
机译:验证了一种快速,灵敏且选择性的液相色谱-串联质谱(LC-MS / MS)方法,然后通过LC-MS / MS方法测定健康成年人血清中的皮质醇和可的松水平。通过添加2 µmL乙酸乙酯直接提取100μL血清样品,然后在C18色谱柱上进行色谱分离,流动相由5 µmM醋酸铵和甲醇(25 +:75,v / v)组成。该方法的精密度,准确度和平均回收率分别为:皮质醇为1.5–5.3%,95.4–102.5%和96.4%,而可的松为1.9–6.0%,89.2–98.8%和79.9%。该方法对皮质醇的线性为1.0至500.0μng/ mL(r 2 = 0.999),对于可的松为2.5至100.0μng/ mL(r 2 = 0.998)。皮质醇的检出限(LOD)和定量限(LOQ)分别为0.2和1.0μng/ mL,可的松分别为1.0和2.5μng/ mL。在9:00至11:00 a.m。之间采集的样品的平均皮质醇浓度(133.9±63.7ng / mL)比可的松(30.5±10.7ngng / mL)高约4.4倍(P <0.0001)。可的松/皮质醇的平均比例为0.225。因此,LC-MS / MS方法可用于诊断某些肾上腺疾病和评估临床实验室中的11β-羟类固醇脱氢酶(11β-HSD)活性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号