首页> 美国卫生研究院文献>Journal of Aerosol Medicine and Pulmonary Drug Delivery >In Vitro Flow Rate Dependency of Delivered Dose and Fine Particle Dose of Salmeterol/Fluticasone Propionate Easyhaler and Seretide Diskus with Patient Flow Rates Collected in a Randomized Controlled Trial
【2h】

In Vitro Flow Rate Dependency of Delivered Dose and Fine Particle Dose of Salmeterol/Fluticasone Propionate Easyhaler and Seretide Diskus with Patient Flow Rates Collected in a Randomized Controlled Trial

机译:沙美特罗/丙酸氟替卡松丙酸Easyhaler和Seretide Diskus的给药剂量和细颗粒剂量的体外流速依赖性以及在随机对照试验中收集的患者流速

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: The Easyhaler® device-metered dry powder inhaler containing Salmeterol and Fluticasone propionate (S/F) has been developed for the treatment of patients with asthma and chronic obstructive pulmonary disease (COPD). We report two studies which evaluated the in vitro flow rate dependence of delivered dose (DD) and fine particle dose (FPD) of S/F Easyhaler versus Seretide Diskus®.>Methods: A randomized controlled trial (RCT) assessed inspiratory flow parameters of S/F Easyhaler and Seretide Diskus in subgroups of patients with asthma (children, adolescents and adults, and elderly) and in COPD patients. The 10th, 50th, and 90th percentile airflow rates were determined and utilized in vitro, to evaluate flow rate dependence of DD and FPD. Flow rate dependence was evaluated relative to the result obtained at the 50th percentile and any values deviating from 100% indicated flow rate dependence. The volumetric flow rate dependence (Q) index derived from FPD at 10th and 90th percentile airflows was also evaluated.>Results: Overall, 227 patients were enrolled and randomized; 216 completed the RCT. In total, 55.5% of patients were female, and the mean age was 46.3 years. Clinically relevant airflow rates (46, 68, and 85 L/min for S/F Easyhaler and 44, 71, and 96 L/min for Seretide Diskus) were carried forward into the in vitro study, which demonstrated similar flow rate dependence of DD and FPD for S/F Easyhaler compared with Seretide Diskus; all values were within ±15% limits across the 10th, 50th, and 90th percentile airflow rates. Q index results suggested that both S/F Easyhaler and Seretide Diskus are medium airflow-dependent products.>Conclusions: Similar in vitro flow rate dependence of DD and FPD was demonstrated for S/F Easyhaler compared with Seretide Diskus, across a range of clinically relevant airflow rates, collected from patients with asthma and COPD.
机译:>背景:已开发出含有沙美特罗和丙酸氟替卡松(S / F)的Easyhaler ®设备计量的干粉吸入器,用于治疗哮喘和慢性阻塞性肺疾病(COPD)。我们报告了两项评估S / F Easyhaler与Seretide Diskus ®的递送剂量(DD)和细颗粒剂量(FPD)的体外流速依赖性的研究。>方法:一项随机对照试验(RCT)评估了哮喘患者(儿童,青少年,成人和老年人)亚组和COPD患者的S / F Easyhaler和Seretide Diskus的吸气流量参数。确定并在体外利用第10,第50和第90个百分位空气流速,以评估DD和FPD的流速依赖性。相对于第50个百分位数获得的结果评估了流速依赖性,任何偏离100%的值都表示流速依赖性。 >结果:总体上,共有227例患者入选并随机分组;其中,FPD得出的体积流量依赖性(Q)指数。 216完成了RCT。共有55.5%的患者为女性,平均年龄为46.3岁。临床相关的气流速率(S / F Easyhaler为46、68和85 L / min,Seretide Diskus为44、71和96 L / min)进入体外研究,表明DD的流速依赖性相似S / F Easyhaler的FPD与Seretide Diskus相比;在第10、50和90%的气流速率下,所有值均在±15%的范围内。 Q指数结果表明S / F Easyhaler和Seretide Diskus都是中等气流依赖性产品。>结论:与Seretide Diskus相比,S / F Easyhaler对DD和FPD的体外流速依赖性相似。从哮喘和COPD患者中收集的一系列临床相关的气流速率下,