Optimal implantation site of transponders for identification of experimentalswine

机译:用于识别实验的应答器的最佳植入位置猪

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Use of transponders, small electronic identification devices, in experimental swine is expected to be more reliable than the current common use of ear tags. However, it is necessary to determine the optimal implantation site for transponders with high readability, retentionability (i.e., long-term retention in tissues without detachment or loss), and biocompatibility, as this has not yet been investigated. Thus, we aimed to determine the optimal implantation site. Two types of transponders were subcutaneously implanted into four different sites (ear base, ear auricle, ventral neck, and back) in 3 domestic swine each. The transponders were scanned at 1, 2, 3, and 84 days after implantation. The location of the transponders was examined by X-ray and echography at 84 days. Histopathological examinations were performed at 84 days. The transponders in the back were successfully scanned in a shorter time than those in other implantation sites, without any re-scanning procedures. X-ray examination revealed one transponder in the ventral neck was lost, whereas those in the other sites were retained in their original location for 84 days. Echography indicated that the transponders in the back were retained more deeply than those in other implantation sites, suggesting better retentionability. Acceptable biocompatibility was confirmed in all implantation sites, as evidenced by the finding that all transponders were covered by a connective tissue capsule without severeinflammation. In conclusion, the present results demonstrated that the back is the optimalimplantation site for transponders in experimental swine.
机译:预期在实验猪中使用应答器(小型电子识别设备)比当前耳标的普遍使用更为可靠。但是,有必要确定具有高可读性,保留能力(即在组织中长期保留而不脱落或丢失)和生物相容性的应答器的最佳植入位置,因为尚未对此进行研究。因此,我们旨在确定最佳的植入部位。将两种类型的应答器分别皮下植入3只家养猪的四个不同部位(耳基,耳廓,腹颈和背部)。植入后第1、2、3和84天扫描应答器。在84天时通过X射线和回波描记术检查了应答器的位置。在第84天进行组织病理学检查。与其他植入位置相比,无需任何重新扫描程序,就可以在更短的时间内成功扫描背面的应答器。 X射线检查显示腹侧颈部一个应答器丢失,而其他部位的应答器则保留在原始位置84天。超声检查表明,与其他植入位点相比,背面的应答器保留得更深,表明保留能力更好。在所有植入部位均证实了可接受的生物相容性,这一发现证明所有应答器均被结缔组织囊覆盖,且没有严重的结局。炎。总之,目前的结果表明,背面是最佳的实验猪的应答器植入位点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号