首页> 美国卫生研究院文献>International Journal of Nanomedicine >Fabrication and physicochemical characterization of porous composite microgranules with selenium oxyanions and risedronate sodium for potential applications in bone tumors
【2h】

Fabrication and physicochemical characterization of porous composite microgranules with selenium oxyanions and risedronate sodium for potential applications in bone tumors

机译:含硒氧阴离子和利塞膦酸钠的多孔复合微粒的制备及理化性质研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Nanocrystalline hydroxyapatite containing selenite ions (SeHA; 9.6 wt.% of selenium) was synthesized using wet method and subject to careful physicochemical analysis by powder X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, solid-state nuclear magnetic resonance, wavelength dispersive X-ray fluorescence, and inductively coupled plasma optical emission spectrometry. SeHA was then used to develop the selenium-containing hydroxyapatite/alginate (SeHA/ALG) composite granules. Risedronate sodium (RIS) was introduced to the obtained spherical microgranules of a size of about 1.1–1.5 mm in 2 ways: during the granules’ preparation (RIS solution added to a suspension of ALG and SeHA), and as a result of SeHA/ALG granules soaking in aqueous RIS solution. The analysis made using 13C and 31P cross-polarization magic angle spinning nuclear magnetic resonance confirmed the presence of RIS and its interaction with calcium ions. Then, the release of selenium (inductively coupled plasma optical emission spectrometry) and RIS (high-performance liquid chromatography) from microgranules was examined. Moreover, cytotoxicity of fabricated granules was assessed by MTT test. Selenium release was biphasic: the first stage was short and ascribed to a “burst release” probably from a hydrated surface layer of SeHA crystals, while the next stage was significantly longer and ascribed to a sustained release of selenium from the crystals’ interior. The study showed that the method of obtaining microgranules containing RIS significantly affects its release profile. Performed cytotoxicity test revealed that fabricated granules had high antitumor activity against osteosarcoma cells. However, because of the “burst release” of selenium during the first 10 h, the granules significantly reduced viability of normal osteoblasts as well.
机译:使用湿法合成了含硒离子的纳米晶羟基磷灰石(SeHA;硒的9.6 wt。%),并通过粉末X射线衍射,傅里叶变换红外光谱,透射电子显微镜,固态核磁共振,波长进行了仔细的理化分析色散X射线荧光和电感耦合等离子体发射光谱法。然后使用SeHA来开发含硒的羟基磷灰石/藻酸盐(SeHA / ALG)复合颗粒。以两种方式将利塞膦酸钠(RIS)引入到大小约为1.1-1.5 mm的球形微颗粒中:在颗粒的制备过程中(将RIS溶液添加到ALG和SeHA的悬浮液中),以及作为SeHA /将ALG颗粒浸泡在RIS水溶液中。使用 13 C和 31 P交叉极化魔角旋转核磁共振进行的分析证实了RIS的存在及其与钙离子的相互作用。然后,检查了微粒中硒的释放(电感耦合等离子体发射光谱法)和RIS(高效液相色谱法)。此外,通过MTT试验评估了制成的颗粒的细胞毒性。硒的释放是双相的:第一阶段很短,可能是由于SeHA晶体的水合表面层“爆发释放”,而下一阶段则明显更长,并且归因于硒从晶体内部的持续释放。研究表明,获得包含RIS的微粒的方法会显着影响其释放曲线。进行的细胞毒性试验表明,制成的颗粒对骨肉瘤细胞具有很高的抗肿瘤活性。但是,由于硒在最初的10小时内“爆炸性释放”,因此颗粒也显着降低了正常成骨细胞的生存能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号