摘要

This study evaluated the sealing ability of apical plugs made of white and gray MTA-Angelus® and white Portland cement placed via the root canal and having different thicknesses (2, 5 and 7 mm). Ninety extracted human single-rooted teeth were instrumented using a size 40 K-file to standardize the foraminal opening by the stepback technique. The teeth were assigned to 3 groups (n=30), according to the material used for fabrication of the apical plugs: A = gray MTA; B = white MTA; C = white Portland cement. The groups were subdivided into groups of 10 teeth each according to the apical plug thickness (2, 5 and 7 mm). Marginal apical dye leakage was assessed using 0.2% Rhodamine B solution in which the specimens were immersed for 72 hours at 37°C. The roots were sectioned longitudinally in a buccolingual direction for apical plug exposure, and digital photographs were taken and analyzed by Image Tool image-analysis software. Data were analyzed statistically by Kruskal-Wallis and Dunn's tests. Significance level was set at 5%. The least percent leakage was observed for 5- and 7-mm-thick plugs (p<0.05). No significant difference (p>0.05) was found between gray MTA and white Portland cement. Among the three materials analyzed, white MTA presented the highest marginal leakage (p<0.05). The findings of the present study showed that gray MTA and Portland cement had better sealing ability than white MTA when used as apical plugs. Dye leakage was smaller for 5- and 7-mm-thick plugs compared to 2-mm-thick plugs.
机译:这项研究评估了由白色和灰色MTA-Angelus®和白色波特兰水泥制成的,通过牙根管放置的,厚度不同(2、5和7 mm)的顶塞的密封能力。使用大小为40 K的锉刀对90颗提取的人类单根牙齿进行了器械测量,以通过后退技术标准化了椎间孔的开口。根据用于制造顶端塞的材料,将牙齿分为3组(n = 30):A =灰色MTA; B =白色MTA; C =白色波特兰水泥。根据顶塞厚度(2、5和7 mm)将这些组分为10个牙齿组。使用0.2%罗丹明B溶液评估边缘顶端染料的渗漏,将样品在37°C下浸泡72小时。沿颊舌方向纵向切开根,以暴露顶尖,并用Image Tool图像分析软件拍摄数字照片并进行分析。数据通过Kruskal-Wallis和Dunn's检验进行统计分析。显着性水平设定为5%。对于5毫米和7毫米厚的塞子,观察到的泄漏百分比最小(p <0.05)。灰色MTA和白色波特兰水泥之间没有显着差异(p> 0.05)。在所分析的三种材料中,白色MTA呈现出最高的边际泄漏(p <0.05)。本研究的结果表明,灰色MTA和波特兰水泥在用作顶塞时比白色MTA具有更好的密封能力。与2毫米厚的塞子相比,5毫米和7毫米厚的塞子的染料泄漏量较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号