Rate of Temperature Decay in Human Muscle Following 3 MHz Ultrasound: The Stretching Window Revealed

机译:3 MHz超声后人体肌肉的温度衰减率:拉伸窗口显露出来

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Researchers have determined that when therapeutic ultrasound vigorously heats connective tissue, it can be effective in increasing extensibility of collagen affected by scar tissue. These findings give credence to the use of continuous thermal ultrasound to heat tissue before stretching, exercise, or friction massage in an effort to decrease joint contractures and increase range of motion. Before our investigation, it was not known how long following an ultrasound treatment the tissue will remain at a vigorous heating level (>3°C). We conducted this study to determine the rate of temperature decay following 3 MHz ultrasound, in order to determine the time period of optimal stretching. Twenty subjects had a 23-gauge hypodermic needle microprobe inserted 1.2 cm deep into the medial aspect of their anesthetized triceps surae muscle. Subjects then received a 3 MHz ultrasound treatment at 1.5 W/cm2 until the tissue temperature was increased at least 5°C. The mean baseline temperature before each treatment was 33.8 ± 1.3°C, and it peaked at 39.1 ± 1.2°C from the ultrasound. Immediately following the treatment, we recorded the rate at which the temperature dropped at 30-second intervals. We ran a stepwise nonlinear regression analysis to predict temperature decay as a function of time following ultrasound treatment. We found a significant nonlinear relationship between time and temperature decay. The average time it took for the temperature to drop each degree as expressed in minutes and seconds was: 1°C = 1:20; 2°C = 3:22; 3°C = 5:50; 4°C = 9:13; 5°C = 14:55; 5.3°C = 18:00 (baseline). We conclude that under similar circumstances where the tissue temperature is raised 5°C, stretching will be effective, on average, for 3.3 minutes following an ultrasound treatment. To increase this stretching window, we suggest that stretching be applied during and immediately after ultrasound application.
机译:研究人员已经确定,当治疗性超声波大力加热结缔组织时,可以有效地增加受瘢痕组织影响的胶原蛋白的可扩展性。这些发现证明了在拉伸,锻炼或摩擦按摩之前使用连续热超声加热组织,以减少关节挛缩并增加运动范围。在我们进行调查之前,尚不知道超声治疗后组织将保持在剧烈加热水平(> 3°C)的时间。我们进行了这项研究,以确定3 MHz超声后的温度衰减率,以确定最佳拉伸的时间段。 20名受试者的23针皮下注射针显微探针插入麻醉的肱三头肌腓肠肌内侧1.2厘米深。然后受试者以1.5 W / cm 2 进行3 MHz超声治疗,直到组织温度至少升高5°C。每次治疗前的平均基线温度为33.8±1.3°C,在超声检查中达到最高峰值39.1±1.2°C。处理后,我们立即记录温度每30秒间隔下降的速率。我们进行了逐步非线性回归分析,以预测超声处理后温度随时间的变化。我们发现时间与温度衰减之间存在显着的非线性关系。温度下降每度所需的平均时间(以分钟和秒为单位)为:1°C = 1:20; 2°C = 3:22; 3°C = 5:50; 4°C = 9:13; 5°C = 14:55; 5.3°C = 18:00(基线)。我们得出的结论是,在组织温度升高5°C的类似情况下,超声波治疗后平均拉伸时间为3.3分钟。为了增加此拉伸窗口,我们建议在超声应用期间和之后立即进行拉伸。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号