摘要

Water in dental unit waterlines (DUWL) represents a risk for vulnerable patients if its microbiological quality is not controlled. The aim of this prospective study was to evaluate two systems for its management under real conditions: Hygowater® and IGN Calbenium®. Samples of the output water of DUWL were obtained for 5 previously contaminated units connected to Hygowater®, and 5 non-contaminated units connected to IGN Calbenium®, which was already effective for more than 1 year, as a control group. Samples were regularly collected up to 6 months after the implementation of Hygowater®, and were then cultured and analyzed. With IGN Calbenium®, except for a technical problem and a sample result in one unit at 6 months (Heterotrophic Plate Count (HPC) at 37 °C of 66 colony forming units (cfu)/mL), the results showed an absence of contamination. Hygowater® took a couple of weeks to be effective on initially contaminated DUWL (over 200 cfu/mL for all the units), then showed its efficacy for 2 months (HPC at 37 °C with a mean of 40.2 ufc/mL, and HPC at 22 °C with a mean of 0.2 ufc/mL). At 6 months, results were satisfactory for HPC at 22 °C (mean of 12 ufc/mL), but HPC at 37 °C gave non-satisfactory results for 4 of the 5 units (mean of 92.2 ufc/mL). Both systems have an effect on the microbiological quality of DUWL. IGN Calbenium® appears to be more reliable on a long-term basis.
机译:牙科单位水有水(DUWL)代表脆弱患者的风险如果没有控制其微生物质量。这项前瞻性研究的目的是根据实际条件评估其管理的两个系统:Hygowater®和IgnCalbenium®。获得DuWL的输出水的样品,获得5个以前的污染的单元,连接到Hygowater®,5个非污染单元,连接到IGNCalbenium®,这已经有效超过1年,作为对照组。在实施Hygowater®的实施后,定期收集样品,然后培养并分析。使用IGNCalbenium®除技术问题外,并在6个月(异养板计数(HPC)为66个菌落形成单位(CFU)/ mL)的单位外,结果表明,结果表明缺乏污染。 Hygowater®在最初受污染的Duwl(所有单位超过200 cfu / ml超过200 cfu / ml)的时间花了几周,然后显示其2个月的功效(37°C的HPC,平均为40.2ufc / ml,以及HPC在22℃下,平均为0.2ufc / ml)。在6个月时,结果在22℃(平均值为12UFC / mL)时,HPC的结果令人满意,但在37℃下的HPC为5个单位的4个(平均值为92.2uFC / ml)。两种系统对Duwl的微生物质量产生了影响。 IGNCalbenium®似乎长期更可靠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号