Antemortem blood biochemical and blood gas analyses are routinely used in health screening and diagnosis of disease in domestic veterinary species. These testing modalities are not routinely performed in poultry, in part, due to the distance from the diagnostic laboratory. Portable blood analyzers such as the i-STAT and VetScan (VS2) can be used to obtain results on the farm without delay, potentially offering a more practical option for poultry practitioners. We investigated the time effect on blood chemistry values and compared the results obtained using the i-STAT and VS2 with those obtained using conventional laboratory analyzers (GEM Premier 3000 and Cobas c501, respectively). We tested blood from 60 healthy chickens. Each sample was tested in triplicate using each of the portable analyzers and once using conventional analyzers. All samples were analyzed within 60 minutes of collection. The concentrations of some analytes were outside the limit of detection of the portable analyzers (i.e., bile acids). Although statistically significant differences were found for some biochemical analytes over time, the actual mean or median differences were too small to be considered of clinical importance. As observed in mammals, significant time-dependent changes in blood gas analytes were observed in whole blood samples exposed to ambient air. Correlation coefficients between portable and conventional analyzers were moderate to high for most of the analytes. For the most part, there was an agreement between the portable and conventional analyzers. We identified constant and proportional biases in the measurement of multiple analytes by both the i-STAT and VS2. Future studies are warranted to establish analyzer-specific reference intervals for poultry.
机译:血管血液生化和血气分析常常用于国内兽医物种的健康筛查和诊断。由于距诊断实验室的距离,这些测试模式在家禽中不常规地进行。诸如I-STAT和VESCAN(VS2)之类的便携式血液分析仪可用于在没有延迟的情况下获得农场的结果,可能为家禽从业者提供更实用的选择。我们调查了对血液化学价值的时间效应,并将使用I-Stat和VS2获得的结果与使用传统实验室分析仪获得的那些(分别是GEM总理3000和COBAS C501)。我们从60只健康的鸡测试血液。使用每个便携式分析仪和一次使用常规分析仪一式三份测试每个样品。在收集的60分钟内分析所有样品。一些分析物的浓度超出了便携式分析仪(即胆汁酸)的检测限。虽然一些生化分析物随时间的生化分析物发现统计学上显着的差异,但实际的平均值或中位差异太小而无法考虑临床重要性。如在哺乳动物中所观察到的,在暴露于环境空气的全血样品中观察到血气分析物的显着时间依赖性变化。对于大多数分析物,便携式和常规分析仪之间的相关系数中等至高。在大多数情况下,便携式和常规分析仪之间存在协议。我们通过I-Stat和VS2识别在测量多个分析物中的常量和比例偏差。未来的研究是有必要建立家禽的分析仪特定的参考间隔。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号