首页> 美国卫生研究院文献>Chronic Respiratory Disease >Reliability and validity of the Glittre-ADL test to assess thefunctional status of patients with interstitial lung disease
【2h】

Reliability and validity of the Glittre-ADL test to assess thefunctional status of patients with interstitial lung disease

机译:Glittre-ADL测试的可靠性和有效性评估间质性肺病患者的功能状态

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The study objective was to investigated the reliability and validity of theADL-Glittre test (TGlittre) to assess the functional status of patients withinterstitial lung disease (ILD). Twenty-one individuals with ILD participated(age: 63 ± 11 years; DLCO: 51.0 ± 12.6%predicted), evaluated with bodyplethysmography, Saint George Respiratory Questionnaire, modified MedicalResearch Council dyspnea scale, six-minute walk test (6MWT) and monitoring ofphysical activity of daily living. Two TGlittre were performed, with an intervalof 30 minutes between them. The TGlittre demonstrated high test-retestreliability, with an intraclass correlation coefficient of 0.90 (95%CI:0.75–0.96; p < 0.001). Nineteen patients (90.5%) performed better on thesecond test (mean difference between TGlittre 1 and 2: −0.57 ± 0.96 minute; p =0.001), with a learning effect of 11.6%. The time in TGlittre correlated with6MWT (r = −0.70; p = 0.002) and with the total energy expenditure in physicalactivity of daily living (r = −0.52; p = 0.02). In %predicted, TGlittre and 6MWTalso correlated (r = −0.50; p = 0.04). Correlations were observed betweenTGlittre and pulmonary function variables (r = −0.47 to −0.57; p = 0.01 to p =0.04). There was no difference in the physiological response between TGlittre 1and 2, and between TGlittre and 6MWT (p > 0.05). In conclusion, the TGlittreis reliable and valid for assessing functional status of patients with ILD.
机译:研究目的是调查了这种可靠性和有效性ADL-Glitttre测试(TGlittre)评估患者的功能状态间质肺病(ILD)。二十一人与ILD的ILD参加(年龄:63±11年; DLCO:预测51.0±12.6%),用身体评估体积描记,圣乔治呼吸问卷,修改医疗研究委员会呼吸困难,六分钟步行检验(6MWT)和监测日常生活的身体活动。进行两根Tglittre,间隔他们之间30分钟。 Tglittre展示了高检重新测试可靠性,具有0.90的脑内相关系数(95%CI:0.75-0.96; p <0.001)。 19名患者(90.5%)对此进行了更好第二种测试(Tglittre 1和2:0.57±0.96分钟的平均差异; P =0.001),学习效果为11.6%。 TGlittre的时间相关6mwt(r = -0.70; p = 0.002),并且物理总能量消耗日常生活活动(r = -0.52; p = 0.02)。在%预测,tglittre和6mwt还相关(r = -0.50; p = 0.04)。之间观察到相关性Tglittre和肺功能变量(r = -0.47至-0.57; p = 0.01至p =0.04)。 Tglittre 1之间的生理反应没有差异2,Tglittre和6MWT(P> 0.05)之间。总之,TGlittre可靠,可用于评估ILD患者的功能状态。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号