首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >First Evaluation of PRISMA Level 1 Data for Water Applications
【2h】

First Evaluation of PRISMA Level 1 Data for Water Applications

机译:第一次评估Prisma级别的水应用数据

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study presents a first assessment of the Top-Of-Atmosphere (TOA) radiances measured in the visible and near-infrared (VNIR) wavelengths from PRISMA (PRecursore IperSpettrale della Missione Applicativa), the new hyperspectral satellite sensor of the Italian Space Agency in orbit since March 2019. In particular, the radiometrically calibrated PRISMA Level 1 TOA radiances were compared to the TOA radiances simulated with a radiative transfer code, starting from in situ measurements of water reflectance. In situ data were obtained from a set of fixed position autonomous radiometers covering a wide range of water types, encompassing coastal and inland waters. A total of nine match-ups between PRISMA and in situ measurements distributed from July 2019 to June 2020 were analysed. Recognising the role of Sentinel-2 for inland and coastal waters applications, the TOA radiances measured from concurrent Sentinel-2 observations were added to the comparison. The results overall demonstrated that PRISMA VNIR sensor is providing TOA radiances with the same magnitude and shape of those in situ simulated (spectral angle difference, SA, between 0.80 and 3.39; root mean square difference, RMSD, between 0.98 and 4.76 [mW m−2 sr−1 nm−1]), with slightly larger differences at shorter wavelengths. The PRISMA TOA radiances were also found very similar to Sentinel-2 data (RMSD < 3.78 [mW m−2 sr−1 nm−1]), and encourage a synergic use of both sensors for aquatic applications. Further analyses with a higher number of match-ups between PRISMA, in situ and Sentinel-2 data are however recommended to fully characterize the on-orbit calibration of PRISMA for its exploitation in aquatic ecosystem mapping.
机译:本研究介绍了在意大利空间机构的新超光谱卫星传感器(Precersore Iperspettale Della MissionEva)的可见和近红外(VNIR)波长中测量的大气层(TOA)辐射的大气层(TOA)辐射的第一次评估自2019年3月以来轨道轨道。特别地,将辐射校准的PRISMA级别1级为1 ~A辐射与用辐射转移代码模拟的TOA辐射进行比较,从原位测量水反射率开始。原位数据是从一组固定位置自治辐射仪获得的,包括各种水类型,包括沿海和内陆水域。分析了Prisma与2019年7月至6月20日至6月20日分布的九场比赛。认识到Sentinel-2对内陆和沿海水域应用的作用,从并发哨声-2观察中测量的TOA辐射被添加到比较中。结果总体上证明了Prisma VNir传感器提供了与原位模拟相同的幅度和形状相同的辐射,在0.80和3.39之间的频谱角差,0.80和3.39之间;均均方差,RMSD在0.98和4.76之间。 2 SR-1 NM-1]),在更短的波长下略大差异。 PRISMA TOA RADIANCE也被发现与Sentinel-2数据非常相似(RMSD <3.78 [MW M-2 SR-1 NM-1]),并鼓励协同使用两种传感器进行水生应用。然而,在PRISMA之间的进一步分析,原位和Sentinel-2数据之间有更多的匹配,以完全表征Prisma的轨道校准,以便在水生生态系统映射中的开发。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号