首页> 美国卫生研究院文献>Journal of Cerebral Blood Flow Metabolism >A method for reducing the effects of motion contamination in arterial spin labeling magnetic resonance imaging
【2h】

A method for reducing the effects of motion contamination in arterial spin labeling magnetic resonance imaging

机译:一种减少运动自旋标记磁共振成像中运动污染影响的方法

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Arterial spin labeling (ASL) is a noninvasive method to measure cerebral blood flow (CBF). Arterial spin labeling is susceptible to artifact generated by head motion; this artifact is propagated through the subtraction procedure required to calculate CBF. We introduce a novel strategy for mitigating this artifact based on weighting tag/control volumes according to a noise estimate. We evaluated this strategy (DVARS weighting) in application to both pulsed ASL (PASL) and pseudo-continuous ASL (pCASL) in a cohort of normal adults (N=57). Application of DVARS weighting significantly improved test–retest repeatability as assessed by the intra-class correlation coefficient. Before the application of DVARS weighting, mean gray matter intra-class correlation (ICC) between subsequent ASL runs was 0.48 and 0.51 in PASL and pCASL, respectively. With weighting, ICC was significantly improved to 0.63 and 0.58.
机译:动脉自旋标记(ASL)是一种无创方法,可测量脑血流量(CBF)。动脉旋转标记易受头部运动产生的伪影的影响;该伪像通过计算CBF所需的减法过程传播。我们根据噪声估计,基于加权标签/控制体积,引入了一种缓解此伪影的新颖策略。我们评估了这一策略(DVARS加权)在正常成年人群(N = 57)中应用于脉冲ASL(PASL)和伪连续ASL(pCASL)的情况。通过类内相关系数评估,DVARS加权的应用显着提高了重测的可重复性。在应用DVARS加权之前,PASL和pCASL中后续ASL运行之间的平均灰质类内相关性(ICC)分别为0.48和0.51。通过加权,ICC显着提高到0.63和0.58。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com