Body-fixed sensor (BFS) technology offers portable, low-cost and easy-to-use alternatives to laboratory-bound equipment for analyzing an individual’s gait. Psychometric properties of single BFS systems for gait analysis in older adults who require a rollator for walking are, however, unknown. The study’s aim was to evaluate the concurrent validity, test-retest-reliability, and sensitivity to change of a BFS (DynaPort MoveTest; McRoberts B.V., The Hague, The Netherlands) for measuring gait parameters during rollator-assisted walking. Fifty-eight acutely hospitalized older patients equipped with the BFS at the lower back completed a 10 m walkway using a rollator. Concurrent validity was assessed against the Mobility Lab (APDM Inc.; Portland, OR, USA), test-retest reliability over two trials within a 15 min period, and sensitivity to change in patients with improved, stable and worsened 4 m usual gait speed over hospital stay. Bland–Altman plots and intraclass correlation coefficients (ICC) for gait speed, cadence, step length, step time, and walk ratio indicate good to excellent agreement between the BFS and the Mobility Lab (ICC2,1 = 0.87–0.99) and the repeated trials (ICC2,1 = 0.83–0.92). Moderate to large standardized response means were observed in improved (gait speed, cadence, step length, walk ratio: 0.62–0.99) and worsened patients (gait speed, cadence, step time: −0.52 to −0.85), while those in stable patients were trivial to small (all gait parameters: −0.04–0.40). The BFS appears to be a valid, reliable and sensitive instrument for measuring spatio-temporal gait parameters during rollator-assisted walking in geriatric patients.
机译:身体固定传感器(BFS)技术提供便携式,低成本,易于使用的替代品,用于分析个人步态。然而,在需要阵列的老年人中,较老成年人步态分析的心理测量特性是未知的。该研究的目的是评估BFS(Dynaport Modetest; McRoberts B.v.,荷兰的McRoberts B.v.,荷兰)的同步有效性,测试 - 重度可靠性和敏感性用于测量汇总步行过程中的步态参数。五十八名急性住院的老年患者,较低背部配备BFS,使用阵列完成了10米的走道。在移动性实验室(APDM Inc.; Portland,USA),在15分钟内的两项试验中进行测试并发有效性,以及在15分钟内的两项试验中的测试,以及改善,稳定和恶化的患者的敏感性4米在住院住宿。 Bland-Altman绘图和脑内相关系数(ICC)用于步态速度,节奏,步长,步进时间和行走比表明BFS和移动实验室之间的优异协议良好(ICC2,1 = 0.87-0.99)和重复的试验(ICC2,1 = 0.83-0.92)。观察到适度的标准化响应手段改进(步态速度,节奏,步长,行走比率:0.62-0.99)和恶化的患者(步态速度,节奏,步进时间:-0.52至-0.85),而稳定患者小于小(所有步态参数:-0.04-0.40)。该BFS似乎是一种有效,可靠和敏感的仪器,用于测量在老年患者的载体辅助行走期间的时空步态参数。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号