首页> 美国卫生研究院文献>Diagnostics >Interobserver Reliability of the Endoscopic Ultrasound Criteria for the Diagnosis of Early Chronic Pancreatitis: Comparison between the 2009 and 2019 Japanese Diagnostic Criteria
【2h】

Interobserver Reliability of the Endoscopic Ultrasound Criteria for the Diagnosis of Early Chronic Pancreatitis: Comparison between the 2009 and 2019 Japanese Diagnostic Criteria

机译:用于诊断早期慢性胰腺炎的内窥镜超声标准的Interobserver可靠性:2009年和2019年日本诊断标准之间的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In 2009, diagnostic criteria for early chronic pancreatitis (DCECP2009) were proposed by the Japan Pancreas Society. This study aimed to evaluate the interobserver reliability (IOR) of endoscopic ultrasound (EUS) criteria for diagnosis of early chronic pancreatitis (ECP) between DCECP2009 and 2019 diagnostic criteria for ECP (DCECP2019) to assess the validity of the revision from the perspective of EUS findings. Among patients who underwent a detailed observation of the pancreas by EUS at our institution between January 2018 and March 2019, EUS images of 97 patients were extracted. Images were reviewed by 12 gastrointestinal endoscopy experts (eight pancreatologists, group A and four nonpancreatologists, group B). The overall kappa (K)-values for the IOR of the DCECP2009 EUS criteria were 0.424 and 0.563:0.231 for groups A:B, whereas the overall K-values for the DCECP2019 criteria were 0.618, and 0.733:0.442 for groups A:B. Regarding changes in the final diagnosis of ECP based on clinical features and EUS findings, 20 cases were definite ECP, 53 were probable ECP, and 24 were normal according to DCECP2009. In contrast, seven were definite ECP, 19 were probable ECP, and 71 were normal according to DECEP2019. IOR of DCECP2019 was higher than that of DCECP2009, which indicates an improvement in precision.
机译:2009年,日本胰腺社会提出了早期慢性胰腺炎(DCECP2009)的诊断标准。本研究旨在评估内窥镜超声(EUS)的interobserver可靠性(IOR),用于诊断ECP(DCECP2019)的DCECP2009和2019诊断标准之间的早期慢性慢性胰腺炎(ECP),以评估eus视角下修订的有效性发现。在2018年1月至2019年1月至2019年3月在2019年3月在我们的机构接受EUS的详细观察患者中,提取了97名患者的EUS图像。通过12个胃肠内窥镜检查专家(八名胰腺学家,A组和四名非丹丹科学家,B组)进行了审查。 DCECP2009 EUS标准的IOR的整体Kappa(K)值为A组为0.424和0.563:0.231,而DCECP2019标准的总K值为0.618,组A:B为0.733:0.442 。关于基于临床特征和EUS发现的ECP最终诊断的变化,20例确定ECP,53例可能是ECP,24例根据DCECP2009正常。相比之下,七个是明确的ECP,19例是可能的ECP,71例,根据Depep2019进行正常情况。 DCECP2019的IOR高于DCECP2009,表明精度提高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号