A prototype of a nitro compound vapor and trace detector, which uses the pyrolysis method and a capacitive gas sensor based on the metal–insulator–semiconductor (MIS) structure type Pd–SiO –Si, was developed and manufactured. It was experimentally established that the detection limit of trinitrotoluene trace for the detector prototype is 1 × 10 g, which corresponds to concentration from 10 g/cm to 10 g/cm . The prototype had a response time of no more than 30 s. The possibility of further improving the characteristics of the prototype detector by reducing the overall dimensions and increasing the sensitivity of the MIS sensors is shown.
机译:开发并制造了一种采用热解方法和基于金属-绝缘体-半导体(MIS)结构类型Pd-SiO-Si的电容式气体传感器的硝基化合物蒸气和痕量检测器的原型。实验确定检测器原型的三硝基甲苯痕量的检测极限为1×10 g,相当于10 g / cm至10 g / cm的浓度。原型的响应时间不超过30秒。显示了通过减小​​整体尺寸并增加MIS传感器的灵敏度来进一步改善原型检测器特性的可能性。