Validity and Reliability of an Inertial Device for Measuring Dynamic Weight-Bearing Ankle Dorsiflexion

机译:惯性装置测量动态负重踝背屈的有效性和可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A decrease in ankle dorsiflexion causes changes in biomechanics, and different instruments have been used for ankle dorsiflexion testing under static conditions. Consequently, the industry of inertial sensors has developed easy-to-use devices, which measure dynamic ankle dorsiflexion and provide additional parameters such as velocity, acceleration, or movement deviation. Therefore, the aims of this study were to analyze the concurrent validity and test-retest reliability of an inertial device for measuring dynamic weight-bearing ankle dorsiflexion. Sixteen participants were tested using an inertial device (WIMU) and a digital inclinometer. Ankle dorsiflexion from left and right ankle repetitions was used for validity analysis, whereas test-retest reliability was analyzed by comparing measurements from the first and second days. The standard error of the measurement (SEM) between the instruments was very low for both ankle measurements (SEM < 0.6°). No significant differences between instruments were found for the left ankle measurement ( > 0.05) even though a significant systematic bias (~1.77°) was found for the right ankle ( = 0.79). R was very close to 1 in the left and right ankles (R = 0.85–0.89) as well as the intraclass correlation coefficient (ICC > 0.95). Test-retest reliability analysis showed that systematic bias was below 1° for both instruments, even though a systematic bias (~1.50°) with small effect size was found in the right ankle ( = 0.49) with WIMU. The ICC was very close to 1 and the coefficient of variation (CV) was lower than 4% in both instruments. Thus, WIMU is a valid and reliable inertial device for measuring dynamic weight-bearing ankle dorsiflexion.
机译:踝背屈的减少会引起生物力学的变化,并且在静态条件下已使用不同的仪器进行踝背屈测试。因此,惯性传感器行业已经开发出易于使用的设备,该设备可测量动态踝背屈并提供其他参数,例如速度,加速度或运动偏差。因此,本研究的目的是分析用于测量动态负重踝背屈的惯性装置的同时有效性和重测可靠性。使用惯性设备(WIMU)和数字测斜仪对16名参与者进行了测试。来自左右脚踝重复的脚踝背屈用于有效性分析,而重测信度则通过比较第一天和第二天的测量值进行分析。两次脚踝测量(SEM <0.6°)时,仪器之间的测量标准误差(SEM)非常低。即使发现右脚踝有显着的系统偏差(〜1.77°)(= 0.79),左脚踝测量的仪器之间也没有显着差异(> 0.05)。 R在左右脚踝处非常接近1(R = 0.85-0.89)以及组内相关系数(ICC> 0.95)。重测信度分析表明,即使在使用WIMU的右脚踝(= 0.49)处发现了具有较小影响范围的系统偏差(〜1.50°),两种仪器的系统偏差也都低于1°。两种仪器的ICC都非常接近1,变异系数(CV)低于4%。因此,WIMU是用于测量动态负重踝背屈的有效且可靠的惯性设备。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号