We compared the BD MAX enteric bacterial panel (EBP) to culture for the detection of Salmonella, Shigella, Campylobacter, and Shiga toxin-producing enterohemorrhagic Escherichia coli (EHEC) O157 in seeded stool samples. The EBP panel demonstrated superior sensitivity and reliably detected Salmonella, EHEC O157, Shigella, and Campylobacter at concentrations 1- to 2-log10 lower than those needed for culture detection.