In Vitro Impact Testing to Simulate Implant-Supported Prosthesis Retrievability in Clinical Practice: Influence of Cement and Abutment Geometry

机译:在临床实践中模拟体外支持的假体可恢复性的体外冲击测试:水泥和基台几何形状的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Cement-retained implant-supported prosthetics are gaining popularity compared to the alternative screw-retained type, a rise that serves to highlight the importance of retrievability. The aim of the present investigation is to determine the influence of luting agent, abutment height and taper angle on the retrievability of abutment–coping cementations. Abutments with different heights and tapers were screwed onto an implant and their cobalt-chrome copings were cemented on the abutments using three different luting agents. The removals were performed by means of Coronaflex . The number of impulses and the forces were recorded and analyzed with a Kruskal–Wallis test. Harvard cement needed the highest number of impulses for retrieval, followed by Telio CS and Temp Bond. However, abutment height and taper showed a greater influence on the cap’s retrievability ( < 0.05). Long and tapered abutments provided the highest percentage of good retrievability. The influence of the luting agent and the abutment geometry on the cap’s retrieval performed by Coronaflex reflects data from literature about the influence of the same factor on the maximum force reached during uniaxial tensile tests. The impulse force was slightly affected by the same factors.
机译:与替代的螺钉固定型相比,用水泥保留的植入物支撑的假体正变得越来越流行,这种上升突出了可回收性的重要性。本研究的目的是确定引诱剂,基台高度和锥角对基台覆盖胶结物的可回收性的影响。将具有不同高度和锥度的基台拧紧到植入物上,并使用三种不同的浸润剂将其钴-铬顶盖粘合到基台上。去除是通过Coronaflex进行的。记录了冲动次数和作用力,并通过Kruskal–Wallis检验进行了分析。哈佛水泥需要最高数量的脉冲来进行取回,其次是Telio CS和Temp Bond。但是,基台的高度和锥度对顶盖的可取性影响更大(<0.05)。细长的基台提供了最高的良好可恢复性百分比。腐蚀剂和基台几何形状对Coronaflex进行的帽盖取回的影响反映了来自文献的数据,该文献涉及相同因素对单轴拉伸试验中达到的最大力的影响。脉冲力受到相同因素的轻微影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号