Mechanical Assessment of Fatigue Characteristics between Single- and Multi-Directional Cyclic Loading Modes on a Dental Implant System

机译:牙科植入系统单向和多向循环加载模式之间疲劳特性的机械评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Mechanical testing based on ISO 14801 standard is generally used to evaluate the performance of the dental implant system according to material and design changes. However, the test method is difficult to reflect on the clinical environment because the ISO 14801 standard does not take into account the various loads from different directions during chewing motion. In addition, the fracture pattern of the implant system can occur both in the horizontal and the vertical directions. Therefore, the purpose of this study was to compare fatigue characteristics and fracture patterns between single directional loading conditions based on the ISO 14801 standard and multi-directional loading condition. Firstly, the static test was performed on five specimens to derive the fatigue load, and the fatigue load was chosen as 40% of the maximum load measured in the static test. Subsequently, the fatigue test was performed considering the single axial/occlusal (AO), AO with facial/lingual (AOFL) and AO with mesial/distal (AOMD) directions, and five specimens were used for each fatigue loading modes. In order to analyze the fatigue characteristics, the fatigue cycle at the time of specimen fracture and displacement change of the specimen every 500 cycles were measured. Field emission scanning electron microscopy (FE-SEM) was used to analyze the fracture patterns and the fracture surface. Compared to the AO group, the fatigue cycle of the AOFL and AOMD groups showed lower about five times, while the displacement gradually increased with every 500 cycles. From FE-SEM results, there were no different surface morphology characteristics among three groups. However, the AOMD group showed a vertical slip band. Therefore, our results suggest that the multi-directional loading mode under the worst-case environment can reproduce the vertical fracture pattern in the clinical situation and may be essential to reflect on the dental implant design including connection types and surface treatments.
机译:通常根据材料和设计变更,使用基于ISO 14801标准的机械测试来评估牙科植入系统的性能。但是,该测试方法很难反映到临床环境中,因为ISO 14801标准没有考虑咀嚼运动过程中来自不同方向的各种载荷。另外,植入物系统的断裂模式可以在水平方向和垂直方向上都发生。因此,本研究的目的是比较基于ISO 14801标准的单向载荷条件与多向载荷条件之间的疲劳特性和断裂模式。首先,对五个试样进行静态测试,得出疲劳载荷,然后选择疲劳载荷为静态测试中测得的最大载荷的40%。随后,在考虑单个轴向/咬合(AO),具有面部/舌侧AO(AOFL)和具有中/远侧(AOMD)方向的AO的条件下进行疲劳测试,每种疲劳载荷模式使用了五个样本。为了分析疲劳特性,每500个循环测量试样断裂时的疲劳循环和试样的位移变化。场发射扫描电子显微镜(FE-SEM)被用来分析断裂模式和断裂表面。与AO组相比,AOFL和AOMD组的疲劳周期降低了约5倍,而位移每500个周期逐渐增加。从FE-SEM结果来看,三组之间没有不同的表面形态特征。但是,AOMD组显示出垂直滑移带。因此,我们的结果表明,在最坏情况下的多向加载模式可以在临床情况下重现垂直骨折模式,并且可能对于反映包括连接类型和表面处理在内的种植牙设计至关重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号