Revision of a Monoblock Metal-on-Metal Cup Using a Dual Mobility Component: Is It a Reasonable Option?

机译:使用双重移动性组件对整体金属杯进行修订:这是一个合理的选择吗?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Revision of large-diameter, monoblock acetabular components for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA) is correlated to a high amount of complications. For this reason, performing a limited revision by conversion to a dual mobility (DM) without acetabular component exchange has been proposed in order to limit these complications. Although DM bearing offers an easy solution avoiding the intraoperative and time-associated complications, concern about polyethylene wear and stability remains due to the difference regarding the design, the coverage angle and the clearance of the two implants. In order to evaluate the performance of this new solution with the new material to prevent the possibility of failure it is essential to conduct a review of the literature A qualitative systematic review of the literature has been conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search of PubMed, EMBASE, Google Scholar, and Scopus for English and French articles between January 2000 and October 2019 was performed, with the primary objective of finding articles about dual mobility bearing coupling with large metal-on-metal cup in the case of hip revision procedure. Various combinations of the key words were used in the search strategy. Thirteen articles with DM bearing mated with MoM cup were analyzed. Of the 130 hip revisions selected, with a follow-up from 6 to 53 months, there were a total of 14 with complications (10.77%): four true dislocations (3.08%); six intra-prosthetic dislocations (IPD, 4.6%), two of which presented plastic deformation and polyethylene wear; four other complications (3.08%), included a cup osteolysis, a clicking noise, a superficial infection and a periprosthetic fracture. All the mentioned true dislocations occurred during the first month while IPDs appeared during the first two years from the index revision. In conclusion, according to the literature analyzed, we can stress that the concerns and doubts about mating a DM bearing with large MoM cup cannot be dissolved. It has been pointed out that a DM bearing is not designed for a MoM cup; it is not mechanically tested on MoM cups, which presents different clearance and coverage angles. Predictable complications may occur, such as IPD, polyethylene wear and true dislocation. These complications have been reported at an even higher rate than they were in the eighties, when the first generation of DM implants were of a lower quality of polyethylene and the characteristic of the design was less optimal than modern ones.
机译:髋关节表面置换术和金属对金属(MoM)全髋关节置换术(THA)的大直径,整体髋臼组件的修订与大量并发症相关。由于这个原因,为了限制这些并发症,已经提出了通过转换成双活动性(DM)而不进行髋臼组件交换来进行有限的修订。尽管DM轴承提供了一种避免术中和与时间相关的并发症的简便解决方案,但由于设计,两个植入物的覆盖角度和间隙不同,人们仍然担心聚乙烯的磨损和稳定性。为了用新材料评估此新解决方案的性能以防止失败的可能性,必须对文献进行审阅已根据《系统评价的首选报告项目》对文献进行了定性的系统审阅。荟萃分析指南。在2000年1月至2019年10月之间,对PubMed,EMBASE,Google Scholar和Scopus的英文和法文文章进行了全面搜索,其主要目的是查找有关双活动轴承与大型金属对金属杯耦合的文章。髋关节翻修手术。搜索策略中使用了关键字的各种组合。分析了13个带有DM轴承和MoM杯配合的物品。在选择的130个髋关节翻修术中,随访6到53个月,总共有14例并发症(占10.77%):四个真正的脱位(3.08%)。六个假体内脱位(IPD,4.6%),其中两个表现出塑性变形和聚乙烯磨损;其他四个并发症(3.08%)包括杯状骨溶解,咔嗒声,表面感染和假体周围骨折。在索引修订后的头两年中,所有提到的真正的错位都发生在第一个月,而IPD出现了。总而言之,根据分析的文献,我们可以强调,关于消除与大型MoM杯配合使用的DM轴承的担忧和疑虑无法解决。有人指出,DM轴承不是为MoM杯设计的;没有在MoM杯上进行机械测试,因为MoM杯具有不同的间隙和覆盖角度。可能会发生可预见的并发症,例如IPD,聚乙烯磨损和真正的脱位。据报道,这些并发症的发生率甚至超过了80年代,当时第一代DM植入物的聚乙烯质量较低,而且设计的特征不如现代的最佳。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号