首页> 美国卫生研究院文献>Materials >Survival Probability Weibull Characteristics Stress Distribution and Fractographic Analysis of Polymer-Infiltrated Ceramic Network Restorations Cemented on a Chairside Titanium Base: An In Vitro and In Silico Study
【2h】

Survival Probability Weibull Characteristics Stress Distribution and Fractographic Analysis of Polymer-Infiltrated Ceramic Network Restorations Cemented on a Chairside Titanium Base: An In Vitro and In Silico Study

机译:在椅边钛基上固结的聚合物浸润陶瓷网络修复体的存活率威布尔特性应力分布和分形分析:一项体外和计算机模拟研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Different techniques are available to manufacture polymer-infiltrated ceramic restorations cemented on a chairside titanium base. To compare the influence of these techniques in the mechanical response, 75 implant-supported crowns were divided in three groups: CME (crown cemented on a mesostructure), a two-piece prosthetic solution consisting of a crown and hybrid abutment; MC (monolithic crown), a one-piece prosthetic solution consisting of a crown; and MP (monolithic crown with perforation), a one-piece prosthetic solution consisting of a crown with a screw access hole. All specimens were stepwise fatigued (50 N in each 20,000 cycles until 1200 N and 350,000 cycles). The failed crowns were inspected under scanning electron microscopy. The finite element method was applied to analyze mechanical behavior under 300 N axial load. Log-Rank ( = 0.17) and Wilcoxon ( = 0.11) tests revealed similar survival probability at 300 and 900 N. Higher stress concentration was observed in the crowns’ emergence profiles. The MP and CME techniques showed similar survival and can be applied to manufacture an implant-supported crown. In all groups, the stress concentration associated with fractographic analysis suggests that the region of the emergence profile should always be evaluated due to the high prevalence of failures in this area.
机译:可采用不同的技术来制造粘结在椅座钛基上的聚合物浸润陶瓷修复体。为了比较这些技术对机械响应的影响,将75个种植体支持的牙冠分为三组:CME(将牙冠粘合在中观结构上),由牙冠和混合基台组成的两件式假体解决方案; MC(整体式冠),由冠组成的一体式假体解决方案;和MP(带穿孔的整体式牙冠),一种整体式假体解决方案,由带螺丝孔的牙冠组成。所有样品都逐步疲劳(每20,000个循环50 N,直到1200 N和350,000循环)。在扫描电子显微镜下检查失败的冠。应用有限元方法分析了300 N轴向载荷下的力学行为。 Log-Rank(= 0.17)和Wilcoxon(= 0.11)测试显示,在300和900 N下的存活概率相似。 MP和CME技术显示出相似的存活率,可用于制造植入物支持的牙冠。在所有组中,与分形分析相关的应力集中表明,由于该区域的故障率很高,因此应始终对出现剖面的区域进行评估。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号