Comparison of point-of-care peripheral perfusion assessment using pulse oximetry sensor with manual capillary refill time: clinical pilot study in the emergency department

机译:使用脉搏血氧饱和度传感器和手动毛细血管补充时间进行即时现场周边灌注评估的比较:急诊科的临床试验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Schema of the device BRT and the standardized visual CRT measurements. CRT was measured using a chronometer. The examiner compressed the fingertip for 5 s, signaled by “start compression” and “release compression” beep sounds. When the fingertip was released from compression, the examiner began the standardized visual CRT measurement. A pulse oximetry sensor was applied, and the fingertip was compressed and released 5 s after starting compression. There is a SD card slot on the back panel of the device. The waveforms of the light intensity were stored in the SD card. The data was calculated by a pre-fixed algorithm
机译:设备BRT的示意图和标准化的可视CRT测量。 CRT使用计时器进行测量。检查员将指尖压紧5秒钟,并通过“开始压缩”和“释放压缩”蜂鸣声发出信号。当指尖从压缩状态释放时,检查者开始进行标准化的视觉CRT测量。应用脉搏血氧饱和度传感器,并在开始压缩后5 s压缩指尖并释放。设备背面板上有一个SD卡插槽。光强度的波形存储在SD卡中。数据是通过预先确定的算法计算的