首页> 美国卫生研究院文献>Journal of Clinical Medicine >Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Subjects
【2h】

Validity and Reliability of a New Optoelectronic System for Measuring Active Range of Motion of Upper Limb Joints in Asymptomatic and Symptomatic Subjects

机译:一种新的光电系统的有效性和可靠性该系统可测量无症状和有症状受试者的上肢关节活动范围

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland–Altmann plots. Intra- and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Both instruments showed excellent correlation for all movements ( range from 0.992 to 0.999). The intra- and inter-rater reliability were excellent (ICC range from 0.95 to 0.99 and 0.90 to 0.98, respectively). Intra-rater reliability showed SEMs <1.38% and <5.19% and inter-rater reliability SEMs <2.26% and <5.22% for asymptomatic and symptomatic, respectively. Veloflex-IDA is a valid and reliable alternative to measure the upper limb joints’ ROM and it can be used in clinical practice and research after basic training.
机译:这项研究的目的是评估Veloflex红外动态角度计(Veloflex-IDA)的有效性以及评估上肢关节运动范围(ROM)时评定者之间和评定者之间的可靠性。评价了35名健康者和20名有症状的参与者。 Veloflex-IDA分两次进行了十二次上肢运动的测量,Veloflex-IDA是一种由照相机组成的设备,可跟踪逆向反射标记的轨迹。此外,在第一节课中使用了测角仪来评估并发有效性。有效性和一致性通过皮尔森相关系数(r)和Bland–Altmann图进行评估。使用组内相关性(ICC),标准测量误差(SEM)和最小可检测变化(MDC)评估评定者内部和评定者之间的可靠性。两种仪器对所有运动均显示出极好的相关性(范围从0.992到0.999)。评估者内部和评估者之间的可靠性极佳(ICC范围分别为0.95至0.99和0.90至0.98)。无症状者和有症状者的SEM可靠性分别为<1.38%和<5.19%,而评分者间可靠性SEM分别为<2.26%和<5.22%。 Veloflex-IDA是测量上肢关节ROM的有效且可靠的替代方法,可在基础训练后用于临床实践和研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号