首页> 美国卫生研究院文献>Journal of Cerebral Blood Flow Metabolism >Phase contrast mapping MRI measurements of global cerebral blood flow across different perfusion states – A direct comparison with 15O-H2O positron emission tomography using a hybrid PET/MR system
【2h】

Phase contrast mapping MRI measurements of global cerebral blood flow across different perfusion states – A direct comparison with 15O-H2O positron emission tomography using a hybrid PET/MR system

机译:相衬映射MRI测量不同灌注状态下的全脑血流的MRI测量–使用混合PET / MR系统与15O-H2O正电子发射断层扫描直接比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Phase-contrast mapping (PCM) magnetic resonance imaging (MRI) provides easy-access non-invasive quantification of global cerebral blood flow (gCBF) but its accuracy in altered perfusion states is not established. We aimed to compare paired PCM MRI and O-H O positron emission tomography (PET) measurements of gCBF in different perfusion states in a single scanning session. Duplicate combined gCBF PCM-MRI and O-H O PET measurements were performed in the resting condition, during hyperventilation and after acetazolamide administration (post-ACZ) using a 3T hybrid PET/MR system. A total of 62 paired gCBF measurements were acquired in 14 healthy young male volunteers. Average gCBF in resting state measured by PCM-MRI and O-H O PET were 58.5 ± 10.7 and 38.6 ± 5.7 mL/100 g/min, respectively, during hyperventilation 33 ± 8.6 and 24.7 ± 5.8 mL/100 g/min, respectively, and post-ACZ 89.6 ± 27.1 and 57.3 ± 9.6 mL/100 g/min, respectively. On average, gCBF measured by PCM-MRI was 49% higher compared to O-H O PET. A strong correlation between the two methods across all states was observed (R  = 0.72,  15O-H O PET, but are associated with a large and non-linear perfusion-dependent difference.
机译:相衬映射(PCM)磁共振成像(MRI)提供了对整体脑血流(gCBF)的易于访问的非侵入性量化方法,但尚未确定其在改变的灌注状态下的准确性。我们的目的是在一次扫描中比较不同灌注状态下gCBF的配对PCM MRI和O-H O正电子发射断层扫描(PET)测量。使用3T混合PET / MR系统在静息状态下,换气过度期间和乙酰唑胺给药后(ACZ后)进行重复的gCBF PCM-MRI和O-H O PET合并测量。在14位健康的年轻男性志愿者中总共获得了62对gCBF测量值。在过度换气期间,通过PCM-MRI和OH O PET测得的静止状态下的平均gCBF分别为58.5±10.7和38.6±5.7 / mL / 100 g / min,而在换气过度时分别为33±8.6和24.7±±5.8 mL / 100 g / min。 ACZ后分别为89.6±27.1和57.3±9.6mL / 100/100 g / min。平均而言,通过PCM-MRI测量的gCBF比O-H O PET高49%。观察到两种方法在所有状态下均具有很强的相关性(R = 0.72,15O-H O PET,但与较大的非线性灌注相关差异相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号