首页> 美国卫生研究院文献>International Journal of Environmental Research and Public Health >Agreement between the Apple Series 1 LifeTrak Core C200 and Fitbit Charge HR with Indirect Calorimetry for Assessing Treadmill Energy Expenditure
【2h】

Agreement between the Apple Series 1 LifeTrak Core C200 and Fitbit Charge HR with Indirect Calorimetry for Assessing Treadmill Energy Expenditure

机译:Apple Series 1LifeTrak Core C200和带有间接量热法的Fitbit Charge HR之间的协议用于评估跑步机的能源支出

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study was to examine agreement in energy expenditure between the Apple Series 1 Watch, LifeTrak Core C200, and Fitbit Charge HR with indirect calorimetry during various treadmill speeds in young adults. Participants were a sample of college-aged students (mean age = 20.1 (1.7) years; 13 females, 17 males). Participants completed six structured 10-minute exercise sessions on a treadmill with speeds ranging from 53.6 m·min to 187.7 m·min . Indirect calorimetry was used as the criterion. Participants wore the Apple Watch, LifeTrak, and Fitbit activity monitors on their wrists. Group-level agreement was examined using equivalence testing, relative agreement was examined using Spearman’s rho, and individual-level agreement was examined using Mean Absolute Percent Error (MAPE) and Bland-Altman Plots. Activity monitor agreement with indirect calorimetry was supported using the Apple Watch at 160.9 m·min (Mean difference = −2.7 kcals, 90% C.I.: −8.3 kcals, 2.8 kcals; MAPE = 11.9%; r = 0.64) and 187.7 m·min (Mean difference = 3.7 kcals, 90% C.I.: −2.2 kcals, 9.7 kcals; MAPE = 10.7%; r = 0.72) and the Fitbit at 187.7 m·min (Mean difference = −0.2 kcals, 90% C.I.: −8.8 kcals, 8.5 kcals; MAPE = 20.1%; r = 0.44). No evidence for statistical equivalence was seen for the LifeTrak at any speed. Bland-Altman Plot Limits of Agreement were narrower for the Apple Series 1 Watch compared to other monitors, especially at slower treadmill speeds. The results support the utility of the Apple Series 1 Watch and Fitbit Charge HR for assessing energy expenditure during specific treadmill running speeds in young adults.
机译:这项研究的目的是研究在青少年跑步机各种速度下,Apple Series 1手表,LifeTrak Core C200和Fitbit Charge HR与间接量热法之间的能源消耗协议。参与者是大学生年龄的样本(平均年龄= 20.1(1.7)岁;女性13位,男性17位)。参与者在跑步机上完成了6次有组织的10分钟运动,速度从53.6 m·min到187.7 m·min不等。间接量热法用作标准。参与者的手腕上戴着Apple Watch,LifeTrak和Fitbit活动监视器。使用等效性检验检查组级别协议,使用Spearman的rho检验相对协议,使用平均绝对百分比误差(MAPE)和Bland-Altman图检查个人级别协议。使用Apple Watch在160.9 m·min(平均差异= -2.7 kcal,90%CI:-8.3 kcal,2.8 kcal; MAPE = 11.9%; r = 0.64)和187.7 m·min的条件下,使用间接量热法进行的活动监视器协议得到支持(平均差异= 3.7 kcals,90%CI:-2.2 kcals,9.7 kcal; MAPE = 10.7%; r = 0.72)和Fitbit在187.7 m·min(平均差异= −0.2 kcals,90%CI:−8.8 kcals ,8.5 kcal; MAPE = 20.1%; r = 0.44)。在任何速度下,都没有发现LifeTrak具有统计等效性的证据。与其他显示器相比,Apple Series 1 Watch的Bland-Altman图解约定限制要窄一些,尤其是在跑步机速度较慢的情况下。结果支持Apple Series 1 Watch和Fitbit Charge HR在评估年轻人特定跑步机运行速度期间的能量消耗时的实用性。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号